Linear Energy Transfer (LET) dependence of graphene oxide dosimeter for different ionizing radiations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F22%3A00562823" target="_blank" >RIV/61389005:_____/22:00562823 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.vacuum.2022.111240" target="_blank" >https://doi.org/10.1016/j.vacuum.2022.111240</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.vacuum.2022.111240" target="_blank" >10.1016/j.vacuum.2022.111240</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Linear Energy Transfer (LET) dependence of graphene oxide dosimeter for different ionizing radiations
Popis výsledku v původním jazyce
The graphene oxide (GO) reduction by ionizing radiation is proportional to the absorbed dose due to the energy release which produces ionizations, deexcitations, chemical bonding breaking, radical formation and recombination, oxygen functional groups and water desorption. Thanks to this, GO can be employed as a dosimeter whose dose can be measured using different analysis techniques, such as Raman spectroscopy, X-ray diffraction (XRD) and Energy Dispersive X-ray (EDX) analysis based on the characteristic X-ray emission, X-ray photoelectron spectroscopy (XPS). To evaluate the GO reduction as a function of the Linear Energy Transfer (LET) of the used radiation, measurements have been performed with XPS and EDX to deduce the C/O atomic ratio versus the X-rays, electron and ion beam energy loss. Results indicate that a linear dependence on LET occurs, as will be presented and discussed.
Název v anglickém jazyce
Linear Energy Transfer (LET) dependence of graphene oxide dosimeter for different ionizing radiations
Popis výsledku anglicky
The graphene oxide (GO) reduction by ionizing radiation is proportional to the absorbed dose due to the energy release which produces ionizations, deexcitations, chemical bonding breaking, radical formation and recombination, oxygen functional groups and water desorption. Thanks to this, GO can be employed as a dosimeter whose dose can be measured using different analysis techniques, such as Raman spectroscopy, X-ray diffraction (XRD) and Energy Dispersive X-ray (EDX) analysis based on the characteristic X-ray emission, X-ray photoelectron spectroscopy (XPS). To evaluate the GO reduction as a function of the Linear Energy Transfer (LET) of the used radiation, measurements have been performed with XPS and EDX to deduce the C/O atomic ratio versus the X-rays, electron and ion beam energy loss. Results indicate that a linear dependence on LET occurs, as will be presented and discussed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vacuum
ISSN
0042-207X
e-ISSN
1879-2715
Svazek periodika
203
Číslo periodika v rámci svazku
SEP
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
111240
Kód UT WoS článku
000865610800001
EID výsledku v databázi Scopus
2-s2.0-85131736228