The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F10%3A00345073" target="_blank" >RIV/61389013:_____/10:00345073 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
Popis výsledku v původním jazyce
The most critical factor in the development of periprosthetic osteolysis (OL) in total hip arthroplasty (THA) is the biological reaction to wear debris. We developed a computational algorithm for calculating the total number of PE particles for volumetric wear when particle size and distribution are known. We demonstrated that total number of PE wear particles strongly depends on their morphology (sizes, size distributions and shapes). These findings suggest that the risk for the development of OL in THA cannot be simply estimated from the volumetric wear alone.
Název v anglickém jazyce
The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
Popis výsledku anglicky
The most critical factor in the development of periprosthetic osteolysis (OL) in total hip arthroplasty (THA) is the biological reaction to wear debris. We developed a computational algorithm for calculating the total number of PE particles for volumetric wear when particle size and distribution are known. We demonstrated that total number of PE wear particles strongly depends on their morphology (sizes, size distributions and shapes). These findings suggest that the risk for the development of OL in THA cannot be simply estimated from the volumetric wear alone.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2B06096" target="_blank" >2B06096: Sledování a minimalizace otěru polymeru UHMWPE v kloubních náhradách</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomedical Materials Research. Part B
ISSN
1552-4973
e-ISSN
—
Svazek periodika
94B
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000278697400020
EID výsledku v databázi Scopus
—