The relationship of polyethylene wear to particle size, distribution, and number: a possible factor explaining the risk of osteolysis after hip arthroplasty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F10%3A10211966" target="_blank" >RIV/61989592:15110/10:10211966 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The relationship of polyethylene wear to particle size, distribution, and number: a possible factor explaining the risk of osteolysis after hip arthroplasty
Popis výsledku v původním jazyce
The most critical factor in the development of periprosthetic osteolysis(Ol) in total hip arthroplasty (THA) is the biological reaction to wear debris. This reaction is dependent, in part, on the size and concentration of particles, which are determinedpredominantly by the polyethylene (PE) wear rate.This implies that the risk developing Ol and prosthesis failure can be estimated from wear measurements. We developeda computational algorithm for calculating the total number of PE particles for volumetric wear when particle size and distribution are known.
Název v anglickém jazyce
The relationship of polyethylene wear to particle size, distribution, and number: a possible factor explaining the risk of osteolysis after hip arthroplasty
Popis výsledku anglicky
The most critical factor in the development of periprosthetic osteolysis(Ol) in total hip arthroplasty (THA) is the biological reaction to wear debris. This reaction is dependent, in part, on the size and concentration of particles, which are determinedpredominantly by the polyethylene (PE) wear rate.This implies that the risk developing Ol and prosthesis failure can be estimated from wear measurements. We developeda computational algorithm for calculating the total number of PE particles for volumetric wear when particle size and distribution are known.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomedical Materials research Part B: Applied Biomaterials
ISSN
1552-4981
e-ISSN
—
Svazek periodika
1
Číslo periodika v rámci svazku
94B
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—