Pre-pulse current measurement of the fast high-current capillary-discharge experiment(2010 IPMHVC)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F10%3A00354066" target="_blank" >RIV/61389021:_____/10:00354066 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pre-pulse current measurement of the fast high-current capillary-discharge experiment(2010 IPMHVC)
Popis výsledku v původním jazyce
Předneseno na konf.:2010 IEEE International Power Modulator and High Voltage Conference,Atlanta,US,23.-27.05.2010,str.172, :We have built two experimental apparatuses CAPEX and CAPEX-U as XUV sources which are based on the fast capillary discharge. On both these devices we have observed lasing at 46.9 nm (Ne-like Ar line). However, these devices are not only lasing at 46.9 nm, but they also use for testing a possibility of amplification at the wavelength below 20 nm, that have more practical applications. Nowadays, the fast high-current capillary-discharge experiments with nitrogen-filled capillary are in progress as well. In this paper the capillary pre-pulse current and its influence on initial conditions (pressure, amplitude, duration) will be studied with the help of spectroscopic measurements.
Název v anglickém jazyce
Pre-pulse current measurement of the fast high-current capillary-discharge experiment(2010 IPMHVC)
Popis výsledku anglicky
Předneseno na konf.:2010 IEEE International Power Modulator and High Voltage Conference,Atlanta,US,23.-27.05.2010,str.172, :We have built two experimental apparatuses CAPEX and CAPEX-U as XUV sources which are based on the fast capillary discharge. On both these devices we have observed lasing at 46.9 nm (Ne-like Ar line). However, these devices are not only lasing at 46.9 nm, but they also use for testing a possibility of amplification at the wavelength below 20 nm, that have more practical applications. Nowadays, the fast high-current capillary-discharge experiments with nitrogen-filled capillary are in progress as well. In this paper the capillary pre-pulse current and its influence on initial conditions (pressure, amplitude, duration) will be studied with the help of spectroscopic measurements.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů