Signal conditioning and processing for metallic Hall sensors.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F17%3A00481377" target="_blank" >RIV/61389021:_____/17:00481377 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.fusengdes.2017.04.106" target="_blank" >http://dx.doi.org/10.1016/j.fusengdes.2017.04.106</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fusengdes.2017.04.106" target="_blank" >10.1016/j.fusengdes.2017.04.106</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Signal conditioning and processing for metallic Hall sensors.
Popis výsledku v původním jazyce
Two electronics prototypes for the ITER outer vessel steady-state magnetic field Hall sensors based ona lock-in signal processing and current spinning technique were developed. The prototypes, the firstusing a rectangular lock-in signal processing with sensor offset cancellation and the second employ-ing advanced lock-in signal processing with sensor and electronics offset cancellation, were comparedwith a DC technique and commercial lock-in amplifier. The influence of long interconnection cables,white noise, and interfering planar Hall effect to a measurement accuracy was evaluated. The planarHall voltage suppression by the current spinning technique was investigated. Whilst the rectangularlock-in amplifier prototype failed to meet the ITER accuracy requirement, the advanced lock-in amplifierprototype demonstrated required functionality and accuracy.
Název v anglickém jazyce
Signal conditioning and processing for metallic Hall sensors.
Popis výsledku anglicky
Two electronics prototypes for the ITER outer vessel steady-state magnetic field Hall sensors based ona lock-in signal processing and current spinning technique were developed. The prototypes, the firstusing a rectangular lock-in signal processing with sensor offset cancellation and the second employ-ing advanced lock-in signal processing with sensor and electronics offset cancellation, were comparedwith a DC technique and commercial lock-in amplifier. The influence of long interconnection cables,white noise, and interfering planar Hall effect to a measurement accuracy was evaluated. The planarHall voltage suppression by the current spinning technique was investigated. Whilst the rectangularlock-in amplifier prototype failed to meet the ITER accuracy requirement, the advanced lock-in amplifierprototype demonstrated required functionality and accuracy.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/LG14002" target="_blank" >LG14002: Přímá vědecká účast v programu termojaderného výzkumu Společného evropského toru JET</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fusion Engineering and Design
ISSN
0920-3796
e-ISSN
—
Svazek periodika
123
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
783-786
Kód UT WoS článku
000418992000163
EID výsledku v databázi Scopus
2-s2.0-85019084915