Calibration of the ITER outer vessel steady-state magnetic sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F21%3A00548224" target="_blank" >RIV/61389021:_____/21:00548224 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378271:_____/21:00548224
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0920379621001745?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0920379621001745?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fusengdes.2021.112398" target="_blank" >10.1016/j.fusengdes.2021.112398</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of the ITER outer vessel steady-state magnetic sensors
Popis výsledku v původním jazyce
The outer vessel steady-state magnetic field sensors (OVSS), a subsystem of the ITER magnetic diagnostics, consists of 60 units that will be installed on the vacuum vessel outer shell. Each OVSS unit features a pair of Hall sensors with a sensing layer made of bismuth and an onboard thermocouple. Prior to the installation of the sensors on ITER, OVSS will be subject to the complex calibration process designed to satisfy the ITER requirement for the measurement accuracy of 4 mT (2σ) in the range of the magnetic field from 0 to 2.5 T. The calibration process includes the calibration of the onboard thermocouple, sensor controller calibration, measurement of tilt of each Hall sensor with respect to the OVSS housing, and the measurement of the sensitivity of Hall sensors as a function of temperature and magnetic field for the range of ITER-relevant magnetic fields and temperatures. The expected calibration error projected to the magnetic field measurement of 2.5 mT will allow to meet the required measurement accuracy.
Název v anglickém jazyce
Calibration of the ITER outer vessel steady-state magnetic sensors
Popis výsledku anglicky
The outer vessel steady-state magnetic field sensors (OVSS), a subsystem of the ITER magnetic diagnostics, consists of 60 units that will be installed on the vacuum vessel outer shell. Each OVSS unit features a pair of Hall sensors with a sensing layer made of bismuth and an onboard thermocouple. Prior to the installation of the sensors on ITER, OVSS will be subject to the complex calibration process designed to satisfy the ITER requirement for the measurement accuracy of 4 mT (2σ) in the range of the magnetic field from 0 to 2.5 T. The calibration process includes the calibration of the onboard thermocouple, sensor controller calibration, measurement of tilt of each Hall sensor with respect to the OVSS housing, and the measurement of the sensitivity of Hall sensors as a function of temperature and magnetic field for the range of ITER-relevant magnetic fields and temperatures. The expected calibration error projected to the magnetic field measurement of 2.5 mT will allow to meet the required measurement accuracy.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fusion Engineering and Design
ISSN
0920-3796
e-ISSN
1873-7196
Svazek periodika
168
Číslo periodika v rámci svazku
July
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
112398
Kód UT WoS článku
000670075300004
EID výsledku v databázi Scopus
2-s2.0-85101779562