Recent improvement of the design of the ITER steady-state magnetic sensors
Popis výsledku v původním jazyce
A recent improvement of the design of the ITER outer vessel steady-state magnetic field sensors (OVSS) is presented. OVSS features a pair of Hall sensors with a sensing layer made of bismuth. Sixty OVSS will be installed on the ITER vacuum vessel outer skin to perform an absolute measurement of magnetic field. The bismuth Hall sensor measurement is temperature dependent, and the maximum allowed OVSS error of 4-mT limits the error of the measurement of the Hall sensor temperature by an on-board thermocouple to be less than 0.28 °C. This error consists of the temperature difference between the thermocouple and Hall sensors, thermocouple calibration error, and thermocouple measurement error. The improved design of the sensor housing reduces the temperature difference between the thermocouple and the Hall sensors bellow 0.04 °C. Procedures of the calibration prior installation and in situ calibration will allow calibrating the on-board thermocouple with the error less than 0.06 °C. The thermocouple measurement error limit was determined as 0.27 °C in which case OVSS meets the maximum allowed error.
Název v anglickém jazyce
Recent improvement of the design of the ITER steady-state magnetic sensors
Popis výsledku anglicky
A recent improvement of the design of the ITER outer vessel steady-state magnetic field sensors (OVSS) is presented. OVSS features a pair of Hall sensors with a sensing layer made of bismuth. Sixty OVSS will be installed on the ITER vacuum vessel outer skin to perform an absolute measurement of magnetic field. The bismuth Hall sensor measurement is temperature dependent, and the maximum allowed OVSS error of 4-mT limits the error of the measurement of the Hall sensor temperature by an on-board thermocouple to be less than 0.28 °C. This error consists of the temperature difference between the thermocouple and Hall sensors, thermocouple calibration error, and thermocouple measurement error. The improved design of the sensor housing reduces the temperature difference between the thermocouple and the Hall sensors bellow 0.04 °C. Procedures of the calibration prior installation and in situ calibration will allow calibrating the on-board thermocouple with the error less than 0.06 °C. The thermocouple measurement error limit was determined as 0.27 °C in which case OVSS meets the maximum allowed error.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Plasma Science
ISSN
0093-3813
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
1276-1280
Kód UT WoS článku
000431521700031
EID výsledku v databázi Scopus