High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F18%3A00492060" target="_blank" >RIV/61389021:_____/18:00492060 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378271:_____/18:00492060
Výsledek na webu
<a href="https://aip.scitation.org/doi/10.1063/1.5038812" target="_blank" >https://aip.scitation.org/doi/10.1063/1.5038812</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5038812" target="_blank" >10.1063/1.5038812</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
Popis výsledku v původním jazyce
The ITER outer vessel steady-state magnetic field sensor diagnostics consists of sixty sensor units. Each sensor unit features a pair of ceramics-metal Hall sensors with a sensing layer made of bismuth. The sensors were tested simultaneously in the magnetic field ranging from -12 T to +12 T at the temperature range from 27 to 127 °C. The Hall coefficient and magnetoresistance of the bismuth layer related to the sensors were identified. In the sensor operating conditions, the Hall coefficient dependence on temperature was fitted with an exponential function with a relative error of less than 0.08%, and the dependence on the magnetic field was fitted with a Gaussian-like function with a relative error of less than 0.11%. An alternative expression based on the physical understanding of the free charge carrier transport in semimetals was derived to describe the dependence of the Hall coefficient on the magnetic field, and its fitting error of 1.2 mT in terms of the magnetic field measurement has met the ITER measurement accuracy requirements.
Název v anglickém jazyce
High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
Popis výsledku anglicky
The ITER outer vessel steady-state magnetic field sensor diagnostics consists of sixty sensor units. Each sensor unit features a pair of ceramics-metal Hall sensors with a sensing layer made of bismuth. The sensors were tested simultaneously in the magnetic field ranging from -12 T to +12 T at the temperature range from 27 to 127 °C. The Hall coefficient and magnetoresistance of the bismuth layer related to the sensors were identified. In the sensor operating conditions, the Hall coefficient dependence on temperature was fitted with an exponential function with a relative error of less than 0.08%, and the dependence on the magnetic field was fitted with a Gaussian-like function with a relative error of less than 0.11%. An alternative expression based on the physical understanding of the free charge carrier transport in semimetals was derived to describe the dependence of the Hall coefficient on the magnetic field, and its fitting error of 1.2 mT in terms of the magnetic field measurement has met the ITER measurement accuracy requirements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000449144500223
EID výsledku v databázi Scopus
2-s2.0-85051518747