Mineral insulated cable assessment for inductive magnetic diagnostic sensors of a hot-wall tokamak
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F19%3A00521626" target="_blank" >RIV/61389021:_____/19:00521626 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/14/09/C09043" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/14/09/C09043</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/09/C09043" target="_blank" >10.1088/1748-0221/14/09/C09043</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mineral insulated cable assessment for inductive magnetic diagnostic sensors of a hot-wall tokamak
Popis výsledku v původním jazyce
The COMPASS-U tokamak, designed to be a 5 T magnetic field device with a full-metal first wall and operating at plasma-facing component temperatures up to 500°C, will start its operation in 2022 at IPP Prague. This device will address ITER and DEMO relevant plasma exhaust physics, including operation with liquid metal divertor. Inductive magnetic diagnostics based on conductive loops of different geometry and orientation are crucial for magnetic confinement fusion devices. Due to the high temperatures of the vacuum vessel upon which they will be operated, a suitable cable insulation needs to be chosen carefully. Mineral-insulated cables (MIC) have proven to be compatible with high baking temperatures. However, the steel sheath of MIC attenuates the response of the sensor at higher frequencies which could affect real-time plasma control feedback and magnetic equilibrium reconstruction. In this work, characterization and testing of multiple MgO MIC of different diameters was conducted. A variety of electrical property measurements, such as frequency attenuation, resistance and capacitance, for each cable is presented, both at low and high temperatures up to 300°C. Cutoff frequencies from 65 kHz to 335 kHz were identified and attributed to the shielding in a flux loop configuration. Using an external RLC circuit, the frequency response of MIC coils is compared to an electrical model for shielded coils, yielding an useful calibrated model for future probe prototypes with different geometries in the frequency range of interest.
Název v anglickém jazyce
Mineral insulated cable assessment for inductive magnetic diagnostic sensors of a hot-wall tokamak
Popis výsledku anglicky
The COMPASS-U tokamak, designed to be a 5 T magnetic field device with a full-metal first wall and operating at plasma-facing component temperatures up to 500°C, will start its operation in 2022 at IPP Prague. This device will address ITER and DEMO relevant plasma exhaust physics, including operation with liquid metal divertor. Inductive magnetic diagnostics based on conductive loops of different geometry and orientation are crucial for magnetic confinement fusion devices. Due to the high temperatures of the vacuum vessel upon which they will be operated, a suitable cable insulation needs to be chosen carefully. Mineral-insulated cables (MIC) have proven to be compatible with high baking temperatures. However, the steel sheath of MIC attenuates the response of the sensor at higher frequencies which could affect real-time plasma control feedback and magnetic equilibrium reconstruction. In this work, characterization and testing of multiple MgO MIC of different diameters was conducted. A variety of electrical property measurements, such as frequency attenuation, resistance and capacitance, for each cable is presented, both at low and high temperatures up to 300°C. Cutoff frequencies from 65 kHz to 335 kHz were identified and attributed to the shielding in a flux loop configuration. Using an external RLC circuit, the frequency response of MIC coils is compared to an electrical model for shielded coils, yielding an useful calibrated model for future probe prototypes with different geometries in the frequency range of interest.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
C09043