Instruments for best target position determination in the high-intensity laser-solid interaction experiment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F23%3A00584204" target="_blank" >RIV/61389021:_____/23:00584204 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378271:_____/23:00584371 RIV/68407700:21340/23:00367468
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12582/2665527/Instruments-for-best-target-position-determination-in-the-high-intensity/10.1117/12.2665527.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12582/2665527/Instruments-for-best-target-position-determination-in-the-high-intensity/10.1117/12.2665527.short</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2665527" target="_blank" >10.1117/12.2665527</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Instruments for best target position determination in the high-intensity laser-solid interaction experiment
Popis výsledku v původním jazyce
We review a number of instruments employed in a high-intensity J-KAREN-P laser-solid interaction experiment and discuss the applicability of the diagnostics to the best target position determination with a ~10 µm accuracy, while the focal spot size was ~1 µm and peak intensity was up to 7×1021 W/cm2. We discuss both front- and back-side diagnostics, some of them operated in the infrared, visible and ultraviolet ranges, while others in the extreme ultraviolet, soft X-ray and gamma-ray ranges. We found that the applicability of some of the instruments to the best at-focus target position determination depends on the thickness of the target.
Název v anglickém jazyce
Instruments for best target position determination in the high-intensity laser-solid interaction experiment
Popis výsledku anglicky
We review a number of instruments employed in a high-intensity J-KAREN-P laser-solid interaction experiment and discuss the applicability of the diagnostics to the best target position determination with a ~10 µm accuracy, while the focal spot size was ~1 µm and peak intensity was up to 7×1021 W/cm2. We discuss both front- and back-side diagnostics, some of them operated in the infrared, visible and ultraviolet ranges, while others in the extreme ultraviolet, soft X-ray and gamma-ray ranges. We found that the applicability of some of the instruments to the best at-focus target position determination depends on the thickness of the target.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering
ISBN
978-151066284-1
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
125820E
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Praha
Datum konání akce
25. 4. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—