A lanthanum bromide detector of runaway electrons for TCV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F25%3A00648099" target="_blank" >RIV/61389021:_____/25:00648099 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/25:00385104
Výsledek na webu
<a href="https://pubs.aip.org/aip/rsi/article/96/9/093501/3361441/A-lanthanum-bromide-detector-of-runaway-electrons" target="_blank" >https://pubs.aip.org/aip/rsi/article/96/9/093501/3361441/A-lanthanum-bromide-detector-of-runaway-electrons</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0277312" target="_blank" >10.1063/5.0277312</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A lanthanum bromide detector of runaway electrons for TCV
Popis výsledku v původním jazyce
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼ 8 M e V on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
Název v anglickém jazyce
A lanthanum bromide detector of runaway electrons for TCV
Popis výsledku anglicky
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼ 8 M e V on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
1089-7623
Svazek periodika
96
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
093501
Kód UT WoS článku
001566040600001
EID výsledku v databázi Scopus
2-s2.0-105015298327