Evaluation and comperison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F01%3A00000003" target="_blank" >RIV/61988987:17110/01:00000003 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Evaluation and comperison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.
Popis výsledku v původním jazyce
The aim of the work was to evaluate the possibilitty to estimate the level of cyclosporin A CyA metabolites as the difference of radioimmunoassay RIA non-specific and RIA specific methods: RIA specific method,RIA non-specific method,and high performanceliquid chromathograpdy method.Although values obtained by RIAsp correlated well those obtained by HPLC,the results of HPLC methods were lower by 8%. The values obtained by RIAns were 2,57 times higher than the values obtained by RIAsp.The combination ofboth the specific and non-specific methods for the determination of CyA presents an improved means for the TDM of CyA and CyA metabolites in renal transplant patients.Moreover,a combination of both methods can help to elucidate some unexpected events,such as the persistence of high cyclosporin blood levels.
Název v anglickém jazyce
Evaluation and comperison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.
Popis výsledku anglicky
Evaluation and comperison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods. RIA specific method,RIA non-specific method,and high performance liquid chromathograpdy method.Although values obtained by RIAsp correlated well those obtained by HPLC,the results of HPLC methods were lower by 8%. The values obtained by RIAns were 2,57 times higher than the values obtained by RIAsp.The combination of both the specific and non-specific methods for the determination of CyA presents an improved means for the TDM of CyA and CyA metabolites in renal transplant patients.Moreover,a combination of both methods can help to elucidate some unexpected events,such as the persistence of highcyclosporin blood levels.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OC%20B15.20" target="_blank" >OC B15.20: Plasmatická hladina cyklosporinu a jeho metabolitů a výskyt nežádoucích účinků (hypertenze, renální toxicita, rejekce) u transplantovaných pacientů. Pk/Pd modelování.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinica Chemica Acta 310
ISSN
—
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
AS - Americká Samoa
Počet stran výsledku
226
Strana od-do
165-171
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—