Capacitive biopotential electrode with a ceramic dielectric layer.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F17%3AA1801MJA" target="_blank" >RIV/61988987:17110/17:A1801MJA - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27240/17:86100277
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0925400517301235" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0925400517301235</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2017.01.116" target="_blank" >10.1016/j.snb.2017.01.116</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capacitive biopotential electrode with a ceramic dielectric layer.
Popis výsledku v původním jazyce
This paper presents the design of an innovative active capacitive electrode with a ceramic dielectric layer. The electrode meets the requirements for contactless measurement, resistance to motion artefacts and possibility to make long and repeated recordings. The proposed capacitive electrode is distinguished from other capacitive electrodes by the construction of the capacitive coupling element, which is placed on the body surface. While common capacitive electrodes use a metal plate with a relatively large surface area as the capacitive coupling element, the proposed electrode uses a dielectric ceramic layer with high permittivity and a surface area no greater than a few cm2. In order to test the electrode, an electrocardiography (ECG) measuring system was designed. Several different dielectric materials, different sizes of the electrode surface, as well as different electronics of the electrode were compared. The results show 26 dB signal to noise ratio (SNR) for the electrode with a ceramic dielectric layer, which was put on a skin over a cotton fabric, compared to 13 dB SNR for an electrode with a metal plate with a four times larger surface area.
Název v anglickém jazyce
Capacitive biopotential electrode with a ceramic dielectric layer.
Popis výsledku anglicky
This paper presents the design of an innovative active capacitive electrode with a ceramic dielectric layer. The electrode meets the requirements for contactless measurement, resistance to motion artefacts and possibility to make long and repeated recordings. The proposed capacitive electrode is distinguished from other capacitive electrodes by the construction of the capacitive coupling element, which is placed on the body surface. While common capacitive electrodes use a metal plate with a relatively large surface area as the capacitive coupling element, the proposed electrode uses a dielectric ceramic layer with high permittivity and a surface area no greater than a few cm2. In order to test the electrode, an electrocardiography (ECG) measuring system was designed. Several different dielectric materials, different sizes of the electrode surface, as well as different electronics of the electrode were compared. The results show 26 dB signal to noise ratio (SNR) for the electrode with a ceramic dielectric layer, which was put on a skin over a cotton fabric, compared to 13 dB SNR for an electrode with a metal plate with a four times larger surface area.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30107 - Medicinal chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators, B: Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
245
Číslo periodika v rámci svazku
1 June 2017
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
988-995
Kód UT WoS článku
000398760700116
EID výsledku v databázi Scopus
2-s2.0-85012992230