MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F19%3AA200247R" target="_blank" >RIV/61988987:17110/19:A200247R - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14740/19:00113263 RIV/61989100:27240/19:10242691
Výsledek na webu
<a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8813026" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8813026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ACCESS.2019.2937624" target="_blank" >10.1109/ACCESS.2019.2937624</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering
Popis výsledku v původním jazyce
This publication describes an original simple low-cost MR fully-compatible and safe fiber-optic breathing sensor (FOBS), which can be used for respiratory triggering and for monitoring the development of respiratory rate within the MR environment and can, thus, serve as prevention from the hyperventilation syndrome. The sensor is created by encapsulation of the Bragg grating into conventional nasal oxygen cannulas. The sensor is immune to minor patient movements, thus limiting movement artifacts to a minimum. Thanks to this fact it can be used for the retrospective/prospective respiratory gating. The sensor is immune to electromagnetic interference (EMI) and can thus be used in any magnetic field (1.5T, 3T, and 7T). The sensor prototype has been tested in both laboratory and real magnetic resonance (3T) environments relative to conventional pneumatic respiration references (PRR). The data measured were statistically evaluated using the objective Bland-Altman method (BAM) and the functionality of the proposed solution was confirmed. Respiratory Triggering functionality was confirmed by the radiologic doctors on the basis of analyzing images using the most used respiratory triggered T2 TSE 3D sequences and by objective method using the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE).
Název v anglickém jazyce
MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering
Popis výsledku anglicky
This publication describes an original simple low-cost MR fully-compatible and safe fiber-optic breathing sensor (FOBS), which can be used for respiratory triggering and for monitoring the development of respiratory rate within the MR environment and can, thus, serve as prevention from the hyperventilation syndrome. The sensor is created by encapsulation of the Bragg grating into conventional nasal oxygen cannulas. The sensor is immune to minor patient movements, thus limiting movement artifacts to a minimum. Thanks to this fact it can be used for the retrospective/prospective respiratory gating. The sensor is immune to electromagnetic interference (EMI) and can thus be used in any magnetic field (1.5T, 3T, and 7T). The sensor prototype has been tested in both laboratory and real magnetic resonance (3T) environments relative to conventional pneumatic respiration references (PRR). The data measured were statistically evaluated using the objective Bland-Altman method (BAM) and the functionality of the proposed solution was confirmed. Respiratory Triggering functionality was confirmed by the radiologic doctors on the basis of analyzing images using the most used respiratory triggered T2 TSE 3D sequences and by objective method using the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015062" target="_blank" >LM2015062: Národní infrastruktura pro biologické a medicínské zobrazování</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE ACCESS
ISSN
2169-3536
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
2019
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
123013-123025
Kód UT WoS článku
000487832300005
EID výsledku v databázi Scopus
—