MRI Diffusion-Weighted Imaging to Measure Infarct Volume: Assessment of Manual Segmentation Variability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F21%3AA2202D8E" target="_blank" >RIV/61988987:17110/21:A2202D8E - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/21:10428585 RIV/00159816:_____/21:00075226 RIV/00843989:_____/21:E0109008 RIV/00216224:14110/21:00122326
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1111/jon.12850" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1111/jon.12850</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jon.12850" target="_blank" >10.1111/jon.12850</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MRI Diffusion-Weighted Imaging to Measure Infarct Volume: Assessment of Manual Segmentation Variability
Popis výsledku v původním jazyce
BACKGROUND AND PURPOSE Manual segmentation of infarct volume on follow-up MRI diffusion-weighted imaging (MRI-DWI) is considered the gold standard but is prone to rater variability. We assess the variability of manual segmentations of MRI-DWI infarct volume. METHODS Consecutive patients (May 2018 to May 2019) with the anterior circulation stroke and endovascularly treated were enrolled. All patients underwent 24- to 32-hour follow-up MRI. Three users manually segmented DWI infarct volumes slice by slice twice. The reference standard of DWI infarct volume was generated by the STAPLE algorithm. Intra- and interrater reliability was evaluated using the intraclass correlation coefficient (ICC) by comparing manual segmentations with the reference standard. Spatial measurements were evaluated using metrics of the Dice similarity coefficient (DSC). Volumetric measurements were compared using the lesion volume. RESULTS The dataset consisted of 44 patients, mean (SD) age was 70.1 years (+/- 10.3), 43% were women, and median baseline NIHSS score was 16. Among three users, the mean DSC for MRI-DWI infarct volume segmentations ranged from 80.6% +/- 11.7% to 88.6% +/- 7.5%, and the mean absolute volume difference was 2.8 +/- 6.8 to 13.0 +/- 14.0 ml. Interrater ICC among the users for DSC and infarct volume was .86 (95% confidence interval [95% CI]: .78-.91) and .997 (95% CI: .995-.998). Intrarater ICC for the three users was .83 (95% CI: .69-.93), .84 (95% CI: .72-.91), and .80 (95% CI: .64-.89) for DSC, and .99 (95% CI: .987-.996), .991 (95% CI: .983-.995), and .996 (95% CI: .993-.998) for infarct volume. CONCLUSIONS Manual segmentation of infarct volume on follow-up MRI-DWI shows excellent agreement and good spatial overlap with the reference standard, suggesting its usefulness for measuring infarct volume on 24- to 32-hour MRI-DWI.
Název v anglickém jazyce
MRI Diffusion-Weighted Imaging to Measure Infarct Volume: Assessment of Manual Segmentation Variability
Popis výsledku anglicky
BACKGROUND AND PURPOSE Manual segmentation of infarct volume on follow-up MRI diffusion-weighted imaging (MRI-DWI) is considered the gold standard but is prone to rater variability. We assess the variability of manual segmentations of MRI-DWI infarct volume. METHODS Consecutive patients (May 2018 to May 2019) with the anterior circulation stroke and endovascularly treated were enrolled. All patients underwent 24- to 32-hour follow-up MRI. Three users manually segmented DWI infarct volumes slice by slice twice. The reference standard of DWI infarct volume was generated by the STAPLE algorithm. Intra- and interrater reliability was evaluated using the intraclass correlation coefficient (ICC) by comparing manual segmentations with the reference standard. Spatial measurements were evaluated using metrics of the Dice similarity coefficient (DSC). Volumetric measurements were compared using the lesion volume. RESULTS The dataset consisted of 44 patients, mean (SD) age was 70.1 years (+/- 10.3), 43% were women, and median baseline NIHSS score was 16. Among three users, the mean DSC for MRI-DWI infarct volume segmentations ranged from 80.6% +/- 11.7% to 88.6% +/- 7.5%, and the mean absolute volume difference was 2.8 +/- 6.8 to 13.0 +/- 14.0 ml. Interrater ICC among the users for DSC and infarct volume was .86 (95% confidence interval [95% CI]: .78-.91) and .997 (95% CI: .995-.998). Intrarater ICC for the three users was .83 (95% CI: .69-.93), .84 (95% CI: .72-.91), and .80 (95% CI: .64-.89) for DSC, and .99 (95% CI: .987-.996), .991 (95% CI: .983-.995), and .996 (95% CI: .993-.998) for infarct volume. CONCLUSIONS Manual segmentation of infarct volume on follow-up MRI-DWI shows excellent agreement and good spatial overlap with the reference standard, suggesting its usefulness for measuring infarct volume on 24- to 32-hour MRI-DWI.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1605" target="_blank" >LQ1605: Translační medicína</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF NEUROIMAGING
ISSN
1051-2284
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
541-550
Kód UT WoS článku
000634712300001
EID výsledku v databázi Scopus
2-s2.0-85103369524