Inter-rater reliability of delirium measuring instruments in patients with locomotive apparatus trauma
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F21%3AA2202DIG" target="_blank" >RIV/61988987:17110/21:A2202DIG - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15120/21:73606769
Výsledek na webu
<a href="https://kont.zsf.jcu.cz/artkey/knt-202101-0005_inter-rater-reliabilita-mericich-nastroju-pro-urceni-deliria-u-pacientu-po-traumatu-pohyboveho-aparatu.php" target="_blank" >https://kont.zsf.jcu.cz/artkey/knt-202101-0005_inter-rater-reliabilita-mericich-nastroju-pro-urceni-deliria-u-pacientu-po-traumatu-pohyboveho-aparatu.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.32725/kont.2021.002" target="_blank" >10.32725/kont.2021.002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inter-rater reliability of delirium measuring instruments in patients with locomotive apparatus trauma
Popis výsledku v původním jazyce
Objective: Determine the results for inter-rater reliability for items in two delirium screening measuring instruments (Delirium Observation Scale, Nursing Delirium Screening Scale). Design: Prospective comparative study of measuring instruments. Methods: Data were collected between August 2018 and August 2019 at the Trauma Clinic, Teaching Hospital, Olomouc, Czech Republic. Study sample included 50 patients with locomotive apparatus trauma, assessed by two raters – general nurses. To assess the inter-rater reliability the study used Cohen’s kappa (κ) method. Results: For the Delirium Observation Scale, the agreement between the two raters for two of the items was 98% (κ = 0.790); for all other items the agreement was 100% (κ = 1.0). The percentage rate of agreement between both raters using the Nursing Delirium Screening Scale was 100% (κ = 1.0) for all five items. Conclusions: For both screening measuring instruments a high level of reliability has been established. Nevertheless, the highest agreement between the raters has been achieved for the Nursing Delirium Screening Scale. The recommendation is to further test the screening delirium measuring instruments in a Czech clinical setting. © 2021 The Authors. Published by University of South Bohemia in České Budějovice, Faculty of Health and Social Sciences.
Název v anglickém jazyce
Inter-rater reliability of delirium measuring instruments in patients with locomotive apparatus trauma
Popis výsledku anglicky
Objective: Determine the results for inter-rater reliability for items in two delirium screening measuring instruments (Delirium Observation Scale, Nursing Delirium Screening Scale). Design: Prospective comparative study of measuring instruments. Methods: Data were collected between August 2018 and August 2019 at the Trauma Clinic, Teaching Hospital, Olomouc, Czech Republic. Study sample included 50 patients with locomotive apparatus trauma, assessed by two raters – general nurses. To assess the inter-rater reliability the study used Cohen’s kappa (κ) method. Results: For the Delirium Observation Scale, the agreement between the two raters for two of the items was 98% (κ = 0.790); for all other items the agreement was 100% (κ = 1.0). The percentage rate of agreement between both raters using the Nursing Delirium Screening Scale was 100% (κ = 1.0) for all five items. Conclusions: For both screening measuring instruments a high level of reliability has been established. Nevertheless, the highest agreement between the raters has been achieved for the Nursing Delirium Screening Scale. The recommendation is to further test the screening delirium measuring instruments in a Czech clinical setting. © 2021 The Authors. Published by University of South Bohemia in České Budějovice, Faculty of Health and Social Sciences.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30307 - Nursing
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Kontakt
ISSN
1212-4117
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
20-24
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85102761828