Combination of water immersion and carbon dioxide insufflation for minimal sedation colonoscopy: a prospective, randomized, single-center trial
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17310%2F12%3AA13014Z7" target="_blank" >RIV/61988987:17310/12:A13014Z7 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Combination of water immersion and carbon dioxide insufflation for minimal sedation colonoscopy: a prospective, randomized, single-center trial
Popis výsledku v původním jazyce
Objective Water immersion insertion and carbon dioxide (CO2) insufflation are able to reduce patient discomfort during and after the procedure. We assessed whether the combination of water immersion and CO2 insufflation is superior in efficacy and patient comfort to other colonoscopic techniques. Methods In a prospective, randomized study, a total of 420 patients were randomized to either water immersion insertion and CO2 insufflation during withdrawal (water/CO2), water insertion and air insufflation during withdrawal (water/air), CO2 insufflation during both insertion and withdrawal (CO2/CO2), or air insufflation during both insertion and withdrawal (air/air). The main outcome was the success of minimal sedation colonoscopy, which was defined as reaching the cecum without switching to another insertion method and without additional sedation beyond the initial 2 mg of midazolam. Patient comfort during and after the procedure was assessed.
Název v anglickém jazyce
Combination of water immersion and carbon dioxide insufflation for minimal sedation colonoscopy: a prospective, randomized, single-center trial
Popis výsledku anglicky
Objective Water immersion insertion and carbon dioxide (CO2) insufflation are able to reduce patient discomfort during and after the procedure. We assessed whether the combination of water immersion and CO2 insufflation is superior in efficacy and patient comfort to other colonoscopic techniques. Methods In a prospective, randomized study, a total of 420 patients were randomized to either water immersion insertion and CO2 insufflation during withdrawal (water/CO2), water insertion and air insufflation during withdrawal (water/air), CO2 insufflation during both insertion and withdrawal (CO2/CO2), or air insufflation during both insertion and withdrawal (air/air). The main outcome was the success of minimal sedation colonoscopy, which was defined as reaching the cecum without switching to another insertion method and without additional sedation beyond the initial 2 mg of midazolam. Patient comfort during and after the procedure was assessed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EUR J GASTROEN HEPAT
ISSN
0954-691X
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
971-977
Kód UT WoS článku
000306289300016
EID výsledku v databázi Scopus
—