The Limiting Content of Combustibles to Prevent Minestone from the Spreading of Fire
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17310%2F23%3AA2402LXP" target="_blank" >RIV/61988987:17310/23:A2402LXP - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27350/23:10254316
Výsledek na webu
<a href="https://www.mdpi.com/1996-1073/16/13/5054" target="_blank" >https://www.mdpi.com/1996-1073/16/13/5054</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/en16135054" target="_blank" >10.3390/en16135054</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Limiting Content of Combustibles to Prevent Minestone from the Spreading of Fire
Popis výsledku v původním jazyce
The limiting content of combustibles to spread/suppress the fire in the minestone of the coal tailing dump (gangue) was studied. This knowledge appears crucial mainly when deciding on the possible usage of minestone as fireproof material for engineering purposes. Theoretical analysis, laboratory experiments as well as scale (in situ) considerations were performed. In the laboratory, a model series of coal–mineral matter mixtures and six representative minestone samples of coal tailing dump (gangue) were investigated. The thermoanalytical (TG/DSC) method was used to evaluate the content of combustibles with their energetic equivalent, EEC (%). The EEC has been suggested as a proper way to quantify the content of combustibles in the samples. Based on the original combustion calorimetric test, an EEC value of 7–9% was found to be a limit between fireproof and fire spreading minestone in a laboratory, while only 2% of combustibles resulted as the limit from the theoretical analysis. On the other hand, respecting real conditions of thermally active dump (Heˇrmanice tailing coal dump), the laboratory limit of 7–9% of EEC was then assessed to shift to the value of about 10 ± 1% for practice.
Název v anglickém jazyce
The Limiting Content of Combustibles to Prevent Minestone from the Spreading of Fire
Popis výsledku anglicky
The limiting content of combustibles to spread/suppress the fire in the minestone of the coal tailing dump (gangue) was studied. This knowledge appears crucial mainly when deciding on the possible usage of minestone as fireproof material for engineering purposes. Theoretical analysis, laboratory experiments as well as scale (in situ) considerations were performed. In the laboratory, a model series of coal–mineral matter mixtures and six representative minestone samples of coal tailing dump (gangue) were investigated. The thermoanalytical (TG/DSC) method was used to evaluate the content of combustibles with their energetic equivalent, EEC (%). The EEC has been suggested as a proper way to quantify the content of combustibles in the samples. Based on the original combustion calorimetric test, an EEC value of 7–9% was found to be a limit between fireproof and fire spreading minestone in a laboratory, while only 2% of combustibles resulted as the limit from the theoretical analysis. On the other hand, respecting real conditions of thermally active dump (Heˇrmanice tailing coal dump), the laboratory limit of 7–9% of EEC was then assessed to shift to the value of about 10 ± 1% for practice.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energies
ISSN
1996-1073
e-ISSN
1996-1073
Svazek periodika
—
Číslo periodika v rámci svazku
June
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
001028071700001
EID výsledku v databázi Scopus
—