The Thermal Performance of Ground Floor Slabs in a Passive House
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F15%3A86095726" target="_blank" >RIV/61989100:27120/15:86095726 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Thermal Performance of Ground Floor Slabs in a Passive House
Popis výsledku v původním jazyce
In this paper are presented detail descriptions of the calculation procedures proposed by the standards for the slab-on-ground heat transfer and the results of an in situ experiment designed to monitor the thermal behaviour of a real slab-on-ground floor. In the following paragraphs are describes and compared the analytical detailed calculation procedure of CSN EN ISO 13370:2009, analytical simplified method of CSN EN 12831:2004 and numerical simulation methods of CSN EN ISO 10211:2009. Different boundary conditions (external design temperatures and external measured temperatures) have been used. The ground temperatures are not included in the calculation procedures, only the thermal conductivity of the ground is respected. In particular, a two-dimensional simulation is compared to data measured from an experimental site over a one year period. Experimental measurements of the subsoil temperature were performed under foundation (at various depths and locations) of the timber-frame buil
Název v anglickém jazyce
The Thermal Performance of Ground Floor Slabs in a Passive House
Popis výsledku anglicky
In this paper are presented detail descriptions of the calculation procedures proposed by the standards for the slab-on-ground heat transfer and the results of an in situ experiment designed to monitor the thermal behaviour of a real slab-on-ground floor. In the following paragraphs are describes and compared the analytical detailed calculation procedure of CSN EN ISO 13370:2009, analytical simplified method of CSN EN 12831:2004 and numerical simulation methods of CSN EN ISO 10211:2009. Different boundary conditions (external design temperatures and external measured temperatures) have been used. The ground temperatures are not included in the calculation procedures, only the thermal conductivity of the ground is respected. In particular, a two-dimensional simulation is compared to data measured from an experimental site over a one year period. Experimental measurements of the subsoil temperature were performed under foundation (at various depths and locations) of the timber-frame buil
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
8th International Conference on Energy Planning, Energy Saving, Environmental Education (EPESE'15)
ISBN
978-1-61804-346-7
ISSN
2227-4359
e-ISSN
—
Počet stran výsledku
6
Strana od-do
163-168
Název nakladatele
WSEAS Press
Místo vydání
[Itálie]
Místo konání akce
Řím
Datum konání akce
7. 11. 2015