Calibration method of Cool Box used for Measuring of Thermal Conductivity Coefficient
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F17%3A86098286" target="_blank" >RIV/61989100:27120/17:86098286 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.861.335" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.861.335</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.861.335" target="_blank" >10.4028/www.scientific.net/AMM.861.335</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration method of Cool Box used for Measuring of Thermal Conductivity Coefficient
Popis výsledku v původním jazyce
One of the methods used for determining the thermal conductivity coefficient of building materials is the Calibrated and Guarded Hot Box method. This method is based on the principle of measuring the heat flux density that passes through the test specimen at a temperature difference between warm and cool parts of the measuring box. For measuring of Thermal Conductivity Coefficient is at the Faculty of Civil Engineering of VŠB TUO uses the Cool Box. Measuring in Cool Box uses the same principle of measuring as Calibrated and Guarded Hot Box. For creating of temperature difference during the measurements at the Cool Box is not used heat, but cold. Measurement of the Thermal Conductivity Coefficient by a Cool Box is very complex in terms of measurement accuracy. That the resulting values as accurate as possible, it is necessary to calibrate itself refrigerated cabinets and all sensors that are used for measurements. This paper describes the principles of calibration of Cool Box and other components, which are used for measuring of the Thermal Conductivity Coefficient of selected natural building materials. Determination of the thermal insulation properties of selected materials is part of a long-term research focused on conventional and unconventional natural building materials.
Název v anglickém jazyce
Calibration method of Cool Box used for Measuring of Thermal Conductivity Coefficient
Popis výsledku anglicky
One of the methods used for determining the thermal conductivity coefficient of building materials is the Calibrated and Guarded Hot Box method. This method is based on the principle of measuring the heat flux density that passes through the test specimen at a temperature difference between warm and cool parts of the measuring box. For measuring of Thermal Conductivity Coefficient is at the Faculty of Civil Engineering of VŠB TUO uses the Cool Box. Measuring in Cool Box uses the same principle of measuring as Calibrated and Guarded Hot Box. For creating of temperature difference during the measurements at the Cool Box is not used heat, but cold. Measurement of the Thermal Conductivity Coefficient by a Cool Box is very complex in terms of measurement accuracy. That the resulting values as accurate as possible, it is necessary to calibrate itself refrigerated cabinets and all sensors that are used for measurements. This paper describes the principles of calibration of Cool Box and other components, which are used for measuring of the Thermal Conductivity Coefficient of selected natural building materials. Determination of the thermal insulation properties of selected materials is part of a long-term research focused on conventional and unconventional natural building materials.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Applied Mechanics and Materials. Volume 861
ISBN
978-3-0357-2070-9
ISSN
1660-9336
e-ISSN
neuvedeno
Počet stran výsledku
8
Strana od-do
335-342
Název nakladatele
Trans Tech Publications
Místo vydání
Durnten-Zurich
Místo konání akce
Brno
Datum konání akce
22. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce