Physical and Numerical Analysis of Corrosion Damage of Prestressing Tendons of the Collapsed Roof Structure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F25%3A10260117" target="_blank" >RIV/61989100:27120/25:10260117 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.prostr.2025.10.018" target="_blank" >http://dx.doi.org/10.1016/j.prostr.2025.10.018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.prostr.2025.10.018" target="_blank" >10.1016/j.prostr.2025.10.018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Physical and Numerical Analysis of Corrosion Damage of Prestressing Tendons of the Collapsed Roof Structure
Popis výsledku v původním jazyce
This conference paper presents the results of a physical and numerical analysis of the effect of corrosion damage on the material properties of prestressing tendons, which were taken from the wreckage of collapsed prestressed roof truss. The main objective of the described research was to evaluate the effect of the depth of corrosion damage on the material properties of prestressing tendons, which were formed by untwisted bundles of patented wires. Corrosion damage was artificially initiated on prestressing tendon samples in a corrosion chamber under the accelerating influence of temperature and salt spray. Test samples of prestressing tendons were stored in a corrosive environment for three exposure time intervals of 60, 100 and 140 days. Corrosion-damaged samples were subsequently subjected to precise spatial scanning with a 3D profilometer, to obtain spatial model of the corrosion-altered surface topography. Subsequently, tensile tests of corrosion-damaged samples and a reference set of samples without corrosion damage were carried out. The data were used to create numerical models of individual test samples and were verified with physical tensile strength tests, evaluated the possibilities of predicting the location of sample failure based on the 3D scan and the shape of corrosion defects, and last but not least, verified the actual weight loss of the material and the volume loss obtained from the 3D model. © © 2025. Published by Elsevier B.V.
Název v anglickém jazyce
Physical and Numerical Analysis of Corrosion Damage of Prestressing Tendons of the Collapsed Roof Structure
Popis výsledku anglicky
This conference paper presents the results of a physical and numerical analysis of the effect of corrosion damage on the material properties of prestressing tendons, which were taken from the wreckage of collapsed prestressed roof truss. The main objective of the described research was to evaluate the effect of the depth of corrosion damage on the material properties of prestressing tendons, which were formed by untwisted bundles of patented wires. Corrosion damage was artificially initiated on prestressing tendon samples in a corrosion chamber under the accelerating influence of temperature and salt spray. Test samples of prestressing tendons were stored in a corrosive environment for three exposure time intervals of 60, 100 and 140 days. Corrosion-damaged samples were subsequently subjected to precise spatial scanning with a 3D profilometer, to obtain spatial model of the corrosion-altered surface topography. Subsequently, tensile tests of corrosion-damaged samples and a reference set of samples without corrosion damage were carried out. The data were used to create numerical models of individual test samples and were verified with physical tensile strength tests, evaluated the possibilities of predicting the location of sample failure based on the 3D scan and the shape of corrosion defects, and last but not least, verified the actual weight loss of the material and the volume loss obtained from the 3D model. © © 2025. Published by Elsevier B.V.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20100 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Procedia Structural Integrity. Volume 73
ISBN
—
ISSN
2452-3216
e-ISSN
—
Počet stran výsledku
7
Strana od-do
112-118
Název nakladatele
Elsevier
Místo vydání
Amsterdam
Místo konání akce
Ostravice
Datum konání akce
28. 5. 2025