STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F10%3A86076497" target="_blank" >RIV/61989100:27200/10:86076497 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
Popis výsledku v původním jazyce
Radon is radioactive gas, which can leak into buildings, where it is concentrating and endangering health of inhabitants. In terms of human health protection at work and in residential buildings, radon can cause high exposures. The first step for qualityprotection against radon is well done measurements. This contribution is focused on a method of evaluation of the integrated electret ion chamber system RM-1 often used in the Czech Republic. This contribution reports five-week long measurements in realconditions, statistical analyses of datasets and a verification of the evaluation method recommended by the manufacturer of the electret device. The statistical verification was carried out by multiple linear regressions using the Statgraphics Plus 5.1software and symbolic regressions using the Eureqa software version 0.79 beta software. Finally, results of integrated measurements are compared with ones taken from the continual radon monitor Radim3As.
Název v anglickém jazyce
STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
Popis výsledku anglicky
Radon is radioactive gas, which can leak into buildings, where it is concentrating and endangering health of inhabitants. In terms of human health protection at work and in residential buildings, radon can cause high exposures. The first step for qualityprotection against radon is well done measurements. This contribution is focused on a method of evaluation of the integrated electret ion chamber system RM-1 often used in the Czech Republic. This contribution reports five-week long measurements in realconditions, statistical analyses of datasets and a verification of the evaluation method recommended by the manufacturer of the electret device. The statistical verification was carried out by multiple linear regressions using the Statgraphics Plus 5.1software and symbolic regressions using the Eureqa software version 0.79 beta software. Finally, results of integrated measurements are compared with ones taken from the continual radon monitor Radim3As.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BB - Aplikovaná statistika, operační výzkum
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M06047" target="_blank" >1M06047: Centrum pro jakost a spolehlivost výroby</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MENDEL 2010, 16th International Conference on Soft Computing
ISBN
978-80-214-4120-0
ISSN
1803-3814
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
University of Technology
Místo vydání
Brno
Místo konání akce
Brno, Czech Republic
Datum konání akce
23. 6. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000288144100081