ABOUT THE DEVELOPMENT OF EXTERNAL FIXATORS APPLIED IN EMERGENCY SURGERY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F13%3A86087625" target="_blank" >RIV/61989100:27230/13:86087625 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00843989:_____/13:E0103711
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ABOUT THE DEVELOPMENT OF EXTERNAL FIXATORS APPLIED IN EMERGENCY SURGERY
Popis výsledku v původním jazyce
At first, the doctors mentioned their own medical experience with treatment of complex pelvic injury in patients with polytrauma and give reasons for necessity of early stabilization of pelvic fractures by means of external fixation, especially with continuous hemorrhage into lesser pelvis region and the retroperitoneum. Afterwards, they used damage control surgery methods including selective embolization. However, this article is focused also on the design of external fixators applied in traumatology and orthopaedics (i.e. skills of engineers). These fixators can be used in the treatment of open and unstable (i.e. complicated) fractures of pelvis and its acetabulum. Two versions (i.e. old and new) are compared. Numerical modelling (i.e. Finite ElementMethod), together with CAD modelling, experiments, material engineering, and nanotechnology are presented as a support for developing of a new design of external fixators.
Název v anglickém jazyce
ABOUT THE DEVELOPMENT OF EXTERNAL FIXATORS APPLIED IN EMERGENCY SURGERY
Popis výsledku anglicky
At first, the doctors mentioned their own medical experience with treatment of complex pelvic injury in patients with polytrauma and give reasons for necessity of early stabilization of pelvic fractures by means of external fixation, especially with continuous hemorrhage into lesser pelvis region and the retroperitoneum. Afterwards, they used damage control surgery methods including selective embolization. However, this article is focused also on the design of external fixators applied in traumatology and orthopaedics (i.e. skills of engineers). These fixators can be used in the treatment of open and unstable (i.e. complicated) fractures of pelvis and its acetabulum. Two versions (i.e. old and new) are compared. Numerical modelling (i.e. Finite ElementMethod), together with CAD modelling, experiments, material engineering, and nanotechnology are presented as a support for developing of a new design of external fixators.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transactions of the VŠB - Technical University of Ostrava, Mechanical Series
ISSN
1210-0471
e-ISSN
—
Svazek periodika
1
Číslo periodika v rámci svazku
LIX
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
77-85
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—