At first, the doctors mentioned their own medical experience with treatment of complex pelvic injury in patients with polytrauma and give reasons for necessity of early stabilization of pelvic fractures by means of external fixation, especially with continuous hemorrhage into lesser pelvis region and the retroperitoneum. Afterwards they used damage control surgery methods including selective embolization. However, this article is focused also on the design of external fixators applied in traumatology and orthopaedics (i.e skills of engineers). These fixators can be used in the treatment of open and unstable (i.e. complicated) fractures of pelvis and its acetabulum. Two versions (i.e. old and new) are compared. Numerical modelling (i.e. Finite Element Method), together with CAD modelling, experiments, material engineering, and nanotechnology are presented as a support for developing of a new design of external fixators.
Název v anglickém jazyce
EXTERNAL FIXATORS APPLIED IN EMERGENCY SURGERY
Popis výsledku anglicky
At first, the doctors mentioned their own medical experience with treatment of complex pelvic injury in patients with polytrauma and give reasons for necessity of early stabilization of pelvic fractures by means of external fixation, especially with continuous hemorrhage into lesser pelvis region and the retroperitoneum. Afterwards they used damage control surgery methods including selective embolization. However, this article is focused also on the design of external fixators applied in traumatology and orthopaedics (i.e skills of engineers). These fixators can be used in the treatment of open and unstable (i.e. complicated) fractures of pelvis and its acetabulum. Two versions (i.e. old and new) are compared. Numerical modelling (i.e. Finite Element Method), together with CAD modelling, experiments, material engineering, and nanotechnology are presented as a support for developing of a new design of external fixators.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Applied Mechanics 2013 : 15th international scientific conference : proceedings of extended abstracts : April 15-18, 2013, Velké Karlovice, Czech Republic
ISBN
978-80-248-2978-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
1-2
Název nakladatele
VŠB - Technická univerzita Ostrava
Místo vydání
Ostrava
Místo konání akce
Velké Karlovice
Datum konání akce
15. 4. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—