Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F09%3A00020983" target="_blank" >RIV/61989100:27240/09:00020983 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement
Popis výsledku v původním jazyce
Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are contact measurement devices which need to be in contact of human body. Secondary they allow only one measurement per several minutes interval (onesper 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measure a blood pressure during a long time period and send this information remotely to operator?s stations. In this station the analysis of receiving video signal is made for several types of usage. In current state we develop a small device to scan a video images throw the NIR CCD camera (Near Infra Red). The video signal istransferred by wireless connection to desktop station where it is analyzed. The first results provide an indication to be a right way to obtain exact continuous blood pressure information.
Název v anglickém jazyce
Architecture of Mobile and Desktop Stations for Noninvasive Continuous Blood Pressure Measurement
Popis výsledku anglicky
Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are contact measurement devices which need to be in contact of human body. Secondary they allow only one measurement per several minutes interval (onesper 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measure a blood pressure during a long time period and send this information remotely to operator?s stations. In this station the analysis of receiving video signal is made for several types of usage. In current state we develop a small device to scan a video images throw the NIR CCD camera (Near Infra Red). The video signal istransferred by wireless connection to desktop station where it is analyzed. The first results provide an indication to be a right way to obtain exact continuous blood pressure information.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFBME Proceedings - World Congress on Medical Physics and Biomedical Engineering
ISBN
—
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Springer
Místo vydání
Berlin/Heidelberg
Místo konání akce
Munich, Germany
Datum konání akce
7. 9. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—