Continuous Noninvasive Blood Pressure Measurement by Near Infra Red CCD Camera and Pulse Transmit Time Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F10%3A86075447" target="_blank" >RIV/61989100:27240/10:86075447 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27360/10:86075447
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuous Noninvasive Blood Pressure Measurement by Near Infra Red CCD Camera and Pulse Transmit Time Systems
Popis výsledku v původním jazyce
The need of continuous blood pressure measurement is usable in wide spectrum of applications from physicians practice to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are contact measurement devices which need to be in contact of human body (hand or foot mainly). Secondary they allow only one measurement per several minutes interval (typically ones in 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measure a blood pressure during a long time period and send this information remotely to operator's stations. We would like to try two systems of blood pressure monitoring. The first one is system with NIR CCD camera (Near Infra Red)...
Název v anglickém jazyce
Continuous Noninvasive Blood Pressure Measurement by Near Infra Red CCD Camera and Pulse Transmit Time Systems
Popis výsledku anglicky
The need of continuous blood pressure measurement is usable in wide spectrum of applications from physicians practice to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are contact measurement devices which need to be in contact of human body (hand or foot mainly). Secondary they allow only one measurement per several minutes interval (typically ones in 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measure a blood pressure during a long time period and send this information remotely to operator's stations. We would like to try two systems of blood pressure monitoring. The first one is system with NIR CCD camera (Near Infra Red)...
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2010 SECOND INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND APPLICATIONS
ISBN
978-0-7695-3982-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IEEE Computer Society
Místo vydání
Los Alamitos, California
Místo konání akce
Bali Isl, INDONESIA
Datum konání akce
19. 3. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000278570200087