A new method for identification of the significant point in the Plethysmografical record
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F10%3A86075808" target="_blank" >RIV/61989100:27240/10:86075808 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/ICSPS.2010.5555642" target="_blank" >http://dx.doi.org/10.1109/ICSPS.2010.5555642</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICSPS.2010.5555642" target="_blank" >10.1109/ICSPS.2010.5555642</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A new method for identification of the significant point in the Plethysmografical record
Popis výsledku v původním jazyce
Photopletysmography (PPG) is a non-invasive, and easy to diagnostic method. It is used in many branches of medicine such as industrial medicine, intensive care, angiology or rheumatology. This examination makes it possible to assess the peripheral bloodcirculation in the vessel bed. It can be helpful in qualitative evaluation of the blood system.[3] Unfortunately, there is not a universal method to assess uniform valuation of the PPG due to the strong variability of the signal and therefore we try to propose an algorithm for systematical diagnostics of plethysmographical record. New algorithm designed for identification of the significant points in the PPG record is described in the paper. The algorithm is based on the continuous wavelet transform (CWT).
Název v anglickém jazyce
A new method for identification of the significant point in the Plethysmografical record
Popis výsledku anglicky
Photopletysmography (PPG) is a non-invasive, and easy to diagnostic method. It is used in many branches of medicine such as industrial medicine, intensive care, angiology or rheumatology. This examination makes it possible to assess the peripheral bloodcirculation in the vessel bed. It can be helpful in qualitative evaluation of the blood system.[3] Unfortunately, there is not a universal method to assess uniform valuation of the PPG due to the strong variability of the signal and therefore we try to propose an algorithm for systematical diagnostics of plethysmographical record. New algorithm designed for identification of the significant points in the PPG record is described in the paper. The algorithm is based on the continuous wavelet transform (CWT).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F1429" target="_blank" >GA102/08/1429: Bezpečnost a zabezpečení aplikací sítí vestavěných systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 2010 International Conference on Signal Processing and Systems
ISBN
978-1-4244-6891-1
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
362-364
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Dalian
Datum konání akce
5. 7. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—