Determination of Network Impedance at the Place of Single-phase Load Connection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F12%3A86082811" target="_blank" >RIV/61989100:27240/12:86082811 - isvavai.cz</a>
Výsledek na webu
<a href="http://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=14&SID=R2dKnjhoNAcBkMAl1gB&page=1&doc=1" target="_blank" >http://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=14&SID=R2dKnjhoNAcBkMAl1gB&page=1&doc=1</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Network Impedance at the Place of Single-phase Load Connection
Popis výsledku v původním jazyce
As shown in the article, the asymmetry is directly proportional to the magnitude of single-phase power and indirectly proportional to three-phase short circuit power of system in the place of connection of load. In the article a ratio is derived betweenthe coefficient of the voltage asymmetry u, the single-phase load S1f and the three-phase short circuit power with improvement of Fortescue´s theory of symmetrical sequence components. With use of this relation is shown an idea to investigate the short circuit power from measured values of the coefficient of the voltage asymmetry u and single-phase load S1f.The results of verification measuring which was realised in a traction transformer substation of electric railways 25 kV; 50 Hz of the Czech railways are mentioned in the article too.
Název v anglickém jazyce
Determination of Network Impedance at the Place of Single-phase Load Connection
Popis výsledku anglicky
As shown in the article, the asymmetry is directly proportional to the magnitude of single-phase power and indirectly proportional to three-phase short circuit power of system in the place of connection of load. In the article a ratio is derived betweenthe coefficient of the voltage asymmetry u, the single-phase load S1f and the three-phase short circuit power with improvement of Fortescue´s theory of symmetrical sequence components. With use of this relation is shown an idea to investigate the short circuit power from measured values of the coefficient of the voltage asymmetry u and single-phase load S1f.The results of verification measuring which was realised in a traction transformer substation of electric railways 25 kV; 50 Hz of the Czech railways are mentioned in the article too.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Przeglad elektrotechniczny
ISSN
0033-2097
e-ISSN
—
Svazek periodika
88
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
2
Strana od-do
264-265
Kód UT WoS článku
000308317800065
EID výsledku v databázi Scopus
—