Software calculation tool for light savings in the buildings compared with real measured data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86086710" target="_blank" >RIV/61989100:27240/13:86086710 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Software calculation tool for light savings in the buildings compared with real measured data
Popis výsledku v původním jazyce
This paper describes modeling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, thecalculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the different parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we canconsider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits. The sample model was compared with measurement of illuminance in the
Název v anglickém jazyce
Software calculation tool for light savings in the buildings compared with real measured data
Popis výsledku anglicky
This paper describes modeling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, thecalculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the different parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we canconsider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits. The sample model was compared with measurement of illuminance in the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th International Scientific Conference Electric Power Engineering 2013
ISBN
978-80-248-2988-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
677-680
Název nakladatele
VŠB - Technická univerzita Ostrava
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou
Datum konání akce
28. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000321920400133