Calculation of saving possibilities in interior lighting system using both daylight and artificial light
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86088605" target="_blank" >RIV/61989100:27240/13:86088605 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calculation of saving possibilities in interior lighting system using both daylight and artificial light
Popis výsledku v původním jazyce
This paper describes modelling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, thecalculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the differents parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we can consider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits.
Název v anglickém jazyce
Calculation of saving possibilities in interior lighting system using both daylight and artificial light
Popis výsledku anglicky
This paper describes modelling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, thecalculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the differents parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we can consider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Przeglad elektrotechniczny
ISSN
0033-2097
e-ISSN
—
Svazek periodika
2013
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
3
Strana od-do
345-347