Monitoring of changes in blood pressure is one the most commonly used medical methods. However as standard procedure it can only be done in discontinuous time intervals. It would be beneficial for diagnostic purposes if it was possible to monitor changesof blood pressure in continuous time intervals. Currently continuous measurement of blood pressure is only possible using invasive methods, which makes the measurement impractical for the doctors and uncomfortable for the patients. Physiologically thereis connection between electrical and mechanical heart functions and blood pressure value. The article describes the method of measurement and ECG and PPG signal processing so as to obtain information about pulse wave transit related to value of blood pressure. This value is called pulse transit time - PTT. The measurement set up used for simultaneous receiving of all necessary biosignals and measurement software in LabView environment for signal processing of the acquired data are descr
Název v anglickém jazyce
Hardware for precise in vivo pulse transmit time CNIBP tests
Popis výsledku anglicky
Monitoring of changes in blood pressure is one the most commonly used medical methods. However as standard procedure it can only be done in discontinuous time intervals. It would be beneficial for diagnostic purposes if it was possible to monitor changesof blood pressure in continuous time intervals. Currently continuous measurement of blood pressure is only possible using invasive methods, which makes the measurement impractical for the doctors and uncomfortable for the patients. Physiologically thereis connection between electrical and mechanical heart functions and blood pressure value. The article describes the method of measurement and ECG and PPG signal processing so as to obtain information about pulse wave transit related to value of blood pressure. This value is called pulse transit time - PTT. The measurement set up used for simultaneous receiving of all necessary biosignals and measurement software in LabView environment for signal processing of the acquired data are descr
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0016" target="_blank" >EE2.3.30.0016: Příležitost pro mladé výzkumníky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2013 International Conference on Applied Electronics : Pilsen, 10-12 September 2013
ISBN
978-80-261-0166-6
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
123-127
Název nakladatele
University of West Bohemia in Pilsen
Místo vydání
Pilsen
Místo konání akce
Plzeň
Datum konání akce
10. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—