Pulse transmit time laboratory measurement solution
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86100511" target="_blank" >RIV/61989100:27240/13:86100511 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3182/20130925-3-CZ-3023.00004" target="_blank" >http://dx.doi.org/10.3182/20130925-3-CZ-3023.00004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3182/20130925-3-CZ-3023.00004" target="_blank" >10.3182/20130925-3-CZ-3023.00004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulse transmit time laboratory measurement solution
Popis výsledku v původním jazyce
It is very important to monitor the patient's reaction to applied treatment at medical procedures. Blood pressure value is one of the important indicators of the patient's health. Blood pressure can be measured continuously, most often by using invasive methods or at defined time intervals during the standard medical examination. For diagnostic purposes, it would be advantage to measure the blood pressure in the long time intervals during the day or medical examination without using invasive methods. This article describes a laboratory experiment exploring the possibility to evaluate the blood pressure by non-invasively measured biosignals ECG and PPG. The value of the blood pressure is evaluated by delay of the pulse wave. This delay is called the pulse transit time-PTT. The article describes the methodology of measurement together with a description of each parts of the measuring chain. Measuring chain is consisting of hardware for the signal measuring and the software created in LabView for signal processing. A case study is used for the acquired data and the data are processed by means of regression analysis. (C) IFAC
Název v anglickém jazyce
Pulse transmit time laboratory measurement solution
Popis výsledku anglicky
It is very important to monitor the patient's reaction to applied treatment at medical procedures. Blood pressure value is one of the important indicators of the patient's health. Blood pressure can be measured continuously, most often by using invasive methods or at defined time intervals during the standard medical examination. For diagnostic purposes, it would be advantage to measure the blood pressure in the long time intervals during the day or medical examination without using invasive methods. This article describes a laboratory experiment exploring the possibility to evaluate the blood pressure by non-invasively measured biosignals ECG and PPG. The value of the blood pressure is evaluated by delay of the pulse wave. This delay is called the pulse transit time-PTT. The article describes the methodology of measurement together with a description of each parts of the measuring chain. Measuring chain is consisting of hardware for the signal measuring and the software created in LabView for signal processing. A case study is used for the acquired data and the data are processed by means of regression analysis. (C) IFAC
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFAC Proceedings Volumes (IFAC-PapersOnline). Volume 12, Issue PART 1
ISBN
978-3-902823-53-3
ISSN
1474-6670
e-ISSN
—
Počet stran výsledku
4
Strana od-do
24-27
Název nakladatele
IFAC
Místo vydání
London
Místo konání akce
Velké Karlovice
Datum konání akce
25. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—