Analyses of Power Quality and Voltage Variation of Photovoltaic Power Plant connected into 22 kV Public Grid
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86088145" target="_blank" >RIV/61989100:27240/13:86088145 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EEEIC-2.2013.6737881" target="_blank" >http://dx.doi.org/10.1109/EEEIC-2.2013.6737881</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EEEIC-2.2013.6737881" target="_blank" >10.1109/EEEIC-2.2013.6737881</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analyses of Power Quality and Voltage Variation of Photovoltaic Power Plant connected into 22 kV Public Grid
Popis výsledku v původním jazyce
Stability of distribution system can be influenced by numerous of installed photovoltaic power plants (PVs). Voltage variations are caused in the connection point of PV due to dynamic variability of power flow from these renewable, but intermittent energy sources. This voltage variation can have wide-spread impact to stability of distribution network, where is PV connected. This paper deals with analysis of one year of PV operation (installed capacity of 1.1 MWp), electric energy flows and voltage variation. By simulation software there will be presented results of voltage variation evaluations and load flow evaluations due to PV?s operation into primary distribution network.
Název v anglickém jazyce
Analyses of Power Quality and Voltage Variation of Photovoltaic Power Plant connected into 22 kV Public Grid
Popis výsledku anglicky
Stability of distribution system can be influenced by numerous of installed photovoltaic power plants (PVs). Voltage variations are caused in the connection point of PV due to dynamic variability of power flow from these renewable, but intermittent energy sources. This voltage variation can have wide-spread impact to stability of distribution network, where is PV connected. This paper deals with analysis of one year of PV operation (installed capacity of 1.1 MWp), electric energy flows and voltage variation. By simulation software there will be presented results of voltage variation evaluations and load flow evaluations due to PV?s operation into primary distribution network.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2013 13th International Conference on Environment and Electrical Engineering : 1-3 November 2013, Wroclaw, Poland : conference proceedings
ISBN
978-1-4799-2802-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
48 - 51
Název nakladatele
IEEE
Místo vydání
Danvers
Místo konání akce
Vratislav
Datum konání akce
1. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—