Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86090040" target="_blank" >RIV/61989100:27240/14:86090040 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/6839425/" target="_blank" >http://ieeexplore.ieee.org/document/6839425/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2014.6839425" target="_blank" >10.1109/EPE.2014.6839425</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard
Popis výsledku v původním jazyce
One link of the production chain of ironworks is sintering. There is a preparation of the ore charge in it, which is transported to the next conveyor system by the bucket excavator. The paper presents results of experimental measurements performed on the bucket loader drive, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of the drive connection. This paper also provides a comparison of levels of monitored voltage characteristics obtained by the measurements to simulated ones, and to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances. Both measurement and simulation confirmed that used input reactor for harmonic mitigation in the drive structure has only very low impact on the level of drawn current and supply voltage distortion. In this paper a simulation is also done for a possibility of using broadband passive harmonic filters to reduce current and voltage distortion. The results show their significant impact on improving quality of drawn current by the drive and supply voltage at the point of its connection.
Název v anglickém jazyce
Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard
Popis výsledku anglicky
One link of the production chain of ironworks is sintering. There is a preparation of the ore charge in it, which is transported to the next conveyor system by the bucket excavator. The paper presents results of experimental measurements performed on the bucket loader drive, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of the drive connection. This paper also provides a comparison of levels of monitored voltage characteristics obtained by the measurements to simulated ones, and to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances. Both measurement and simulation confirmed that used input reactor for harmonic mitigation in the drive structure has only very low impact on the level of drawn current and supply voltage distortion. In this paper a simulation is also done for a possibility of using broadband passive harmonic filters to reduce current and voltage distortion. The results show their significant impact on improving quality of drawn current by the drive and supply voltage at the point of its connection.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Scientific Conference on Electric Power Engineering. Volume 15
ISBN
978-1-4799-3807-0
ISSN
2376-5623
e-ISSN
—
Počet stran výsledku
5
Strana od-do
201-205
Název nakladatele
IEEE
Místo vydání
Danvers
Místo konání akce
Brno
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000358740100038