Analysis and Simulation of Disturbance of Saw Drive in Billet Mill
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F15%3A86094552" target="_blank" >RIV/61989100:27240/15:86094552 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis and Simulation of Disturbance of Saw Drive in Billet Mill
Popis výsledku v původním jazyce
The paper presents results of experimental measurements performed on the main drive of a saw using for division of mill products, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of connection of the saw adjustable speed drive. This paper also provides a comparison of levels of monitored voltage total harmonic distortion THD and voltage harmonics obtained by the measurements to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2. The performed measurements showed high levels of voltage distortion. So in this paper a simulation is also done for a possibility of using broadband passive harmonic filter to improve quality of drive supply voltage. The results show its significant impact onimproving quality of drawn current by the drive and supply voltage at the point of its connection. In the case the decreased voltage distortion is required, the application of this broadband passive harmonic filter could be recommended.
Název v anglickém jazyce
Analysis and Simulation of Disturbance of Saw Drive in Billet Mill
Popis výsledku anglicky
The paper presents results of experimental measurements performed on the main drive of a saw using for division of mill products, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of connection of the saw adjustable speed drive. This paper also provides a comparison of levels of monitored voltage total harmonic distortion THD and voltage harmonics obtained by the measurements to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2. The performed measurements showed high levels of voltage distortion. So in this paper a simulation is also done for a possibility of using broadband passive harmonic filter to improve quality of drive supply voltage. The results show its significant impact onimproving quality of drawn current by the drive and supply voltage at the point of its connection. In the case the decreased voltage distortion is required, the application of this broadband passive harmonic filter could be recommended.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings Of The 8th International Scientific Symposium On Electrical Power Engineering (Elektroenergetika 2015)
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
472-475
Název nakladatele
TECHNICAL UNIV KOSICE, FAC ELECTRICAL ENGRG & INFORMATICS
Místo vydání
Košice
Místo konání akce
Stara Lesna
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000361561700116