ADVANCES IN DEVELOPMENT OF IMAGING DEVICE FOR PLAQUE MEASUREMENT IN AREA OF CAROTID ARTERY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86091024" target="_blank" >RIV/61989100:27240/14:86091024 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27230/14:86091024 RIV/61989100:27740/14:86091024
Výsledek na webu
<a href="http://www.tandfonline.com/doi/abs/10.1080/13102818.2014.910362#.VLlEAC7-XIg" target="_blank" >http://www.tandfonline.com/doi/abs/10.1080/13102818.2014.910362#.VLlEAC7-XIg</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/13102818.2014.910362" target="_blank" >10.1080/13102818.2014.910362</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ADVANCES IN DEVELOPMENT OF IMAGING DEVICE FOR PLAQUE MEASUREMENT IN AREA OF CAROTID ARTERY
Popis výsledku v původním jazyce
This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is oneof the most common causes of ischemic stroke and, therefore, we consider the measurement of the plaque as extremely important. The paper describes the proposed hardware for enhancing the standard ultrasonic probe to provide a possibility of accurate probe positioning and synchronization with the cardiac activity, allowing the precise plaque measurements that were impossible with the standard equipment. The synchronization signal is derived from the output signal of the patient monitor (electrocardiogram (ECG)), processed by a microcontroller-based system, generating the control commands for the linear motion moving the probe. The controlling algorithm synchronizes the movement with the ECG waveform to obtain clear images not disturbed
Název v anglickém jazyce
ADVANCES IN DEVELOPMENT OF IMAGING DEVICE FOR PLAQUE MEASUREMENT IN AREA OF CAROTID ARTERY
Popis výsledku anglicky
This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is oneof the most common causes of ischemic stroke and, therefore, we consider the measurement of the plaque as extremely important. The paper describes the proposed hardware for enhancing the standard ultrasonic probe to provide a possibility of accurate probe positioning and synchronization with the cardiac activity, allowing the precise plaque measurements that were impossible with the standard equipment. The synchronization signal is derived from the output signal of the patient monitor (electrocardiogram (ECG)), processed by a microcontroller-based system, generating the control commands for the linear motion moving the probe. The controlling algorithm synchronizes the movement with the ECG waveform to obtain clear images not disturbed
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biotechnology and Biotechnological Equipment
ISSN
1310-2818
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
BG - Bulharská republika
Počet stran výsledku
5
Strana od-do
355-359
Kód UT WoS článku
000342313600027
EID výsledku v databázi Scopus
—