Indirect-contact surface electrocardiography measurements by capacitive electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86096669" target="_blank" >RIV/61989100:27240/14:86096669 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-02913-9_169" target="_blank" >http://dx.doi.org/10.1007/978-3-319-02913-9_169</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-02913-9_169" target="_blank" >10.1007/978-3-319-02913-9_169</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Indirect-contact surface electrocardiography measurements by capacitive electrodes
Popis výsledku v původním jazyce
This article describes electrocardiography measurements using capacitively coupled electrodes. The advantage of this measurement type lies in an indirect-contact between the electrode surface and skin and movement artifact protection. The measurement iseasier and more comfortable since capacitively coupled electrodes eliminate the need for conductive gel and direct skin contact with the electrodes. The indirect- contact measurement is also suitable for long-term measurements, where in conductive gel desiccation resulted in loss of contact between the electrode and skin. There is also discussed the electrical design of the indirect-contact ECG prototype mentioned above and the accompanying electrodes along with practical measurements in sitting and lying position with various artifact types. This article serves as a preliminary study of indirect-contact ECG with future intention to implement this system within textile products for sophisticated, comfortable and non-obtrusive ECG measur
Název v anglickém jazyce
Indirect-contact surface electrocardiography measurements by capacitive electrodes
Popis výsledku anglicky
This article describes electrocardiography measurements using capacitively coupled electrodes. The advantage of this measurement type lies in an indirect-contact between the electrode surface and skin and movement artifact protection. The measurement iseasier and more comfortable since capacitively coupled electrodes eliminate the need for conductive gel and direct skin contact with the electrodes. The indirect- contact measurement is also suitable for long-term measurements, where in conductive gel desiccation resulted in loss of contact between the electrode and skin. There is also discussed the electrical design of the indirect-contact ECG prototype mentioned above and the accompanying electrodes along with practical measurements in sitting and lying position with various artifact types. This article serves as a preliminary study of indirect-contact ECG with future intention to implement this system within textile products for sophisticated, comfortable and non-obtrusive ECG measur
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings, Volume 43
ISBN
978-3-319-02912-2
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
663-666
Název nakladatele
Springer Verlag
Místo vydání
London
Místo konání akce
Singapur
Datum konání akce
4. 12. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—