Dry contact less surface electrodes for bioelectrical measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86092909" target="_blank" >RIV/61989100:27240/14:86092909 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6822438&tag=1" target="_blank" >http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6822438&tag=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SAMI.2014.6822438" target="_blank" >10.1109/SAMI.2014.6822438</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dry contact less surface electrodes for bioelectrical measurements
Popis výsledku v původním jazyce
This paper describes design and testing of bioelectrical measurement by capacity electrodes. The advantage of this measurement type lies in an indirect-contact between the electrode surface and skin and movement artifact protection. The measurement is easier and more comfortable since capacitively coupled electrodes eliminate the need for conductive gel and direct skin contact with the electrodes. The indirect-contact measurement is also suitable for long-term measurements, where in conductive gel desiccation resulted in loss of contact between the electrode and skin. There is also discussed the electrical design of the indirect-contact ECG prototype mentioned above and the accompanying electrodes along with practical measurements in sitting and lyingposition with various artifact types. This article serves as a preliminary study of indirect-contact ECG with future intention to implement this system within textile products for sophisticated, comfortable and non-obtrusive ECG measureme
Název v anglickém jazyce
Dry contact less surface electrodes for bioelectrical measurements
Popis výsledku anglicky
This paper describes design and testing of bioelectrical measurement by capacity electrodes. The advantage of this measurement type lies in an indirect-contact between the electrode surface and skin and movement artifact protection. The measurement is easier and more comfortable since capacitively coupled electrodes eliminate the need for conductive gel and direct skin contact with the electrodes. The indirect-contact measurement is also suitable for long-term measurements, where in conductive gel desiccation resulted in loss of contact between the electrode and skin. There is also discussed the electrical design of the indirect-contact ECG prototype mentioned above and the accompanying electrodes along with practical measurements in sitting and lyingposition with various artifact types. This article serves as a preliminary study of indirect-contact ECG with future intention to implement this system within textile products for sophisticated, comfortable and non-obtrusive ECG measureme
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
SAMI 2014 - IEEE 12th International Symposium on Applied Machine Intelligence and Informatics, Proceedings
ISBN
978-1-4799-3442-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
357-360
Název nakladatele
IEEE Computer Society
Místo vydání
Los Alamitos
Místo konání akce
Herl'any
Datum konání akce
23. 1. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—