Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A10238273" target="_blank" >RIV/61989100:27240/16:10238273 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85009154186&origin=resultslist&sort=plf-f&src=s&sid=12dbc4f787ba2bb7465c10eb7fb2756b&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2836537543900%29&relpos=54&citeCnt=3&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85009154186&origin=resultslist&sort=plf-f&src=s&sid=12dbc4f787ba2bb7465c10eb7fb2756b&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2836537543900%29&relpos=54&citeCnt=3&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EMBC.2016.7591842" target="_blank" >10.1109/EMBC.2016.7591842</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis
Popis výsledku v původním jazyce
Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) device was custom-designed to collect and analyze the arterial pulse in the wrist. The proposed device is comprised of an optical sensor to monitor arterial pulse, a signal conditioning unit to filter and amplify the analog PPG signal, a microcontroller to digitize the analog PPG signal, and a Bluetooth module to transfer the data to a smart device. This paper proposes a novel model to represent the PPG signal as the summation of two Gaussian functions. The paper concludes with a verification procedure for HRV signal analysis during sedentary activities. © 2016 IEEE.
Název v anglickém jazyce
Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis
Popis výsledku anglicky
Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) device was custom-designed to collect and analyze the arterial pulse in the wrist. The proposed device is comprised of an optical sensor to monitor arterial pulse, a signal conditioning unit to filter and amplify the analog PPG signal, a microcontroller to digitize the analog PPG signal, and a Bluetooth module to transfer the data to a smart device. This paper proposes a novel model to represent the PPG signal as the summation of two Gaussian functions. The paper concludes with a verification procedure for HRV signal analysis during sedentary activities. © 2016 IEEE.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2016
ISBN
978-1-4577-0220-4
ISSN
1557-170X
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
4967-4970
Název nakladatele
Institute of Electrical and Electronics Engineers
Místo vydání
New York
Místo konání akce
Orlando
Datum konání akce
16. 8. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000399823505078