The use of multichannel photoplethysmography for the analysis of heart rate variability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10238391" target="_blank" >RIV/61989100:27240/17:10238391 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/chapter/10.1007/978-981-10-5122-7_208" target="_blank" >https://link.springer.com/chapter/10.1007/978-981-10-5122-7_208</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-5122-7_208" target="_blank" >10.1007/978-981-10-5122-7_208</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of multichannel photoplethysmography for the analysis of heart rate variability
Popis výsledku v původním jazyce
Heart rate variability (HRV) is a parameter of heart reactivity which is used to describe fluctuation of intervals between two consecutive heart beats. The paper focuses on the analysis of HRV from PPG and ECG signals derived from multichannel PPG. The suitable methods of preprocessing of signals are described in order to obtain the accurate result of HRV analysis and several effects causing changes in HRV are evaluated. Its object is to evaluate accuracy of the measurement from PPG beside ECG because this method is not used in common practise and analyse the changes of HRV during day. © Springer Nature Singapore Pte Ltd. 2018.
Název v anglickém jazyce
The use of multichannel photoplethysmography for the analysis of heart rate variability
Popis výsledku anglicky
Heart rate variability (HRV) is a parameter of heart reactivity which is used to describe fluctuation of intervals between two consecutive heart beats. The paper focuses on the analysis of HRV from PPG and ECG signals derived from multichannel PPG. The suitable methods of preprocessing of signals are described in order to obtain the accurate result of HRV analysis and several effects causing changes in HRV are evaluated. Its object is to evaluate accuracy of the measurement from PPG beside ECG because this method is not used in common practise and analyse the changes of HRV during day. © Springer Nature Singapore Pte Ltd. 2018.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings. Volume 65
ISBN
978-981-10-5121-0
ISSN
1680-0737
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
831-834
Název nakladatele
Springer
Místo vydání
Singapur
Místo konání akce
Tampere
Datum konání akce
11. 6. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—