Diagnosis of vascular access for hemodialysis using software application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86099575" target="_blank" >RIV/61989100:27240/16:86099575 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-29236-6_40" target="_blank" >http://dx.doi.org/10.1007/978-3-319-29236-6_40</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-29236-6_40" target="_blank" >10.1007/978-3-319-29236-6_40</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnosis of vascular access for hemodialysis using software application
Popis výsledku v původním jazyce
Sufficient blood flow in arteriovenous shunt (AVS) is one of the key parameters for successful and effective hemodialysis treatment. The development flow is monitored using a blood temperature monitor (BTM), which is a module which based on the thermodilution method can measure recirculation in the AVS. From the measured recirculation, then we can calculate the flow rate in AVS. Subsequent calculations and interpretation of measured data has to choose the appropriate type of software that users, and physicians provides a comprehensive picture of the patient's vascular access. Flow measurement in vascular access AVS in the department of chronic hemodialysis has long been monitored by Doppler ultrasound examination, which is considered a basic examination. Flow measurement in AVS using BTM module can be considered as an alternative method of measurement. (C) ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering 2016.
Název v anglickém jazyce
Diagnosis of vascular access for hemodialysis using software application
Popis výsledku anglicky
Sufficient blood flow in arteriovenous shunt (AVS) is one of the key parameters for successful and effective hemodialysis treatment. The development flow is monitored using a blood temperature monitor (BTM), which is a module which based on the thermodilution method can measure recirculation in the AVS. From the measured recirculation, then we can calculate the flow rate in AVS. Subsequent calculations and interpretation of measured data has to choose the appropriate type of software that users, and physicians provides a comprehensive picture of the patient's vascular access. Flow measurement in vascular access AVS in the department of chronic hemodialysis has long been monitored by Doppler ultrasound examination, which is considered a basic examination. Flow measurement in AVS using BTM module can be considered as an alternative method of measurement. (C) ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering 2016.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TG01010137" target="_blank" >TG01010137: PRE SEED fond VŠB-Technické univerzity Ostrava</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Lecture Notes of the Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering, LNICST. Volume 165
ISBN
978-3-319-29235-9
ISSN
1867-8211
e-ISSN
—
Počet stran výsledku
8
Strana od-do
420-427
Název nakladatele
Springer Verlag
Místo vydání
London
Místo konání akce
Vung Tau
Datum konání akce
26. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce