Comparison of BCG, PCG and ECG signals in application of heart rate monitoring of the human body
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10238500" target="_blank" >RIV/61989100:27240/17:10238500 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85043236731&origin=resultslist&sort=plf-f&src=s&st1=nedoma%2c+j&st2=&sid=6ebb644c129757b8a6e89b8c28526752&sot=b&sdt=b&sl=20&s=FIRSTAUTH%28nedoma%2c+j%29&relpos=1&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85043236731&origin=resultslist&sort=plf-f&src=s&st1=nedoma%2c+j&st2=&sid=6ebb644c129757b8a6e89b8c28526752&sot=b&sdt=b&sl=20&s=FIRSTAUTH%28nedoma%2c+j%29&relpos=1&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TSP.2017.8076019" target="_blank" >10.1109/TSP.2017.8076019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of BCG, PCG and ECG signals in application of heart rate monitoring of the human body
Popis výsledku v původním jazyce
The aim of this article is evaluation and comparison of three different signals from three different sensors in application of monitoring the Heart Rate (HR) of the human body. Authors assembled two different types of fiber optic sensors. The first type of sensor uses Fiber Bragg Grating (FBG) and monitoring of heart rate is based on Ballistocardiography (BCG) principle. The second type of sensor utilizes fiber interferometer and monitoring of heart rate is based on Phonocardiography (PCG). Evaluation of signal from the first two types of sensors was acquired by proposed Optical Interrogators. In case of third type (reference signal), heart rate signal was acquired with the use of standard gel electrodes and modules fixed to the monitored person’s chest using a real-time monitoring system for an Electrocardiography (ECG) with virtual instrumentation (National Instruments ELVIS II). The experimental tests were carried out on six subjects of both sexes in a laboratory conditions with their written consent. The obtained data were compared objectively by the Bland-Altman method.
Název v anglickém jazyce
Comparison of BCG, PCG and ECG signals in application of heart rate monitoring of the human body
Popis výsledku anglicky
The aim of this article is evaluation and comparison of three different signals from three different sensors in application of monitoring the Heart Rate (HR) of the human body. Authors assembled two different types of fiber optic sensors. The first type of sensor uses Fiber Bragg Grating (FBG) and monitoring of heart rate is based on Ballistocardiography (BCG) principle. The second type of sensor utilizes fiber interferometer and monitoring of heart rate is based on Phonocardiography (PCG). Evaluation of signal from the first two types of sensors was acquired by proposed Optical Interrogators. In case of third type (reference signal), heart rate signal was acquired with the use of standard gel electrodes and modules fixed to the monitored person’s chest using a real-time monitoring system for an Electrocardiography (ECG) with virtual instrumentation (National Instruments ELVIS II). The experimental tests were carried out on six subjects of both sexes in a laboratory conditions with their written consent. The obtained data were compared objectively by the Bland-Altman method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0217" target="_blank" >EE2.3.20.0217: Rozvoj excelence vědeckovýzkumného týmu Telekomunikační techniky ve vazbě na zahraniční spolupráci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2017 40th International Conference on Telecommunications and Signal Processing, TSP 2017
ISBN
978-1-5090-3982-1
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
5
Strana od-do
420-424
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Barcelona
Datum konání akce
5. 7. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—