<a href="https://www2.scopus.com/record/display.uri?eid=2-s2.0-85072137699&origin=resultslist&sort=plf-f&src=s&sid=9e59cfd35d01edd2f564836ed20b1587&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=9&citeCnt=0&searchTerm=" target="_blank" >https://www2.scopus.com/record/display.uri?eid=2-s2.0-85072137699&origin=resultslist&sort=plf-f&src=s&sid=9e59cfd35d01edd2f564836ed20b1587&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=9&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fiber-optic technology: Non-invasive monitoring sensor of the human body
Popis výsledku v původním jazyce
This paper deals with a non-invasive monitoring sensor based on two Fiber Bragg Gratings encapsulated in interesting body-inert material entitled fiberglass. The proposal sensor integrates three monitoring sensors into one compact sensor which can measure Respiratory Rate (RR), Heart Rate (HR) and Body Temperature (BT) simultaneously. Functionality and accuracy of the sensor were verified by the laboratory tests performing on 8 volunteers (both genders) with their written consent. All tests showed satisfactory accuracy based on the objective Bland-Altman method with a small relative error below 5 %. The innovative benefit is the minimum probe thickness of 1 mm.
Název v anglickém jazyce
Fiber-optic technology: Non-invasive monitoring sensor of the human body
Popis výsledku anglicky
This paper deals with a non-invasive monitoring sensor based on two Fiber Bragg Gratings encapsulated in interesting body-inert material entitled fiberglass. The proposal sensor integrates three monitoring sensors into one compact sensor which can measure Respiratory Rate (RR), Heart Rate (HR) and Body Temperature (BT) simultaneously. Functionality and accuracy of the sensor were verified by the laboratory tests performing on 8 volunteers (both genders) with their written consent. All tests showed satisfactory accuracy based on the objective Bland-Altman method with a small relative error below 5 %. The innovative benefit is the minimum probe thickness of 1 mm.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20203 - Telecommunications
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Centrum výzkumu pokročilých mechatronických systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of optoelectronics and advanced materials
ISSN
1454-4164
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
5-6
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
7
Strana od-do
306-312
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85072137699