Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F20%3A10244265" target="_blank" >RIV/61989100:27240/20:10244265 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-030-31635-8_197" target="_blank" >http://dx.doi.org/10.1007/978-3-030-31635-8_197</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-030-31635-8_197" target="_blank" >10.1007/978-3-030-31635-8_197</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device
Popis výsledku v původním jazyce
Nowadays, the use of X-ray is an important part of imaging techniques used in medicine. The resulting skiagraphy images are kept in the workplace and can be influenced by secondary radiation, which occurs as a secondary effect when irradiated with X-rays. This secondary radiance has not to effect only for the skiagraphy images but also for the human body. The effect of secondary radiation is irreversible image acquisition, which can lead to poor diagnosis and poor clinical information. Currently, there are no techniques and methods available to determine the extent of secondary damage to the skiagraphy cassette. In the work, we analyse the influence of secondary radiation on the quality of the skiagraphy images using mobile X-ray devices. During image analysis, a multi-region segmentation method is used to determine pixels that are affected by irradiation. By this method, we are able to derive the characteristics of the image, determine the level of irradiation and estimate the effect of secondary radiation. (C) 2020, Springer Nature Switzerland AG.
Název v anglickém jazyce
Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device
Popis výsledku anglicky
Nowadays, the use of X-ray is an important part of imaging techniques used in medicine. The resulting skiagraphy images are kept in the workplace and can be influenced by secondary radiation, which occurs as a secondary effect when irradiated with X-rays. This secondary radiance has not to effect only for the skiagraphy images but also for the human body. The effect of secondary radiation is irreversible image acquisition, which can lead to poor diagnosis and poor clinical information. Currently, there are no techniques and methods available to determine the extent of secondary damage to the skiagraphy cassette. In the work, we analyse the influence of secondary radiation on the quality of the skiagraphy images using mobile X-ray devices. During image analysis, a multi-region segmentation method is used to determine pixels that are affected by irradiation. By this method, we are able to derive the characteristics of the image, determine the level of irradiation and estimate the effect of secondary radiation. (C) 2020, Springer Nature Switzerland AG.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20600 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings. Volume 76
ISBN
978-3-030-31634-1
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
10
Strana od-do
1599-1608
Název nakladatele
Springer
Místo vydání
Cham
Místo konání akce
Coimbra
Datum konání akce
26. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—