The characterization of D-T neutron generators in precise neutron experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F22%3A10249866" target="_blank" >RIV/61989100:27240/22:10249866 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/26722445:_____/22:N0000063 RIV/00216224:14330/22:00128968
Výsledek na webu
<a href="https://www.sciencedirect.com/journal/nuclear-instruments-and-methods-in-physics-research-section-a-accelerators-spectrometers-detectors-and-associated-equipment" target="_blank" >https://www.sciencedirect.com/journal/nuclear-instruments-and-methods-in-physics-research-section-a-accelerators-spectrometers-detectors-and-associated-equipment</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2022.166837" target="_blank" >10.1016/j.nima.2022.166837</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The characterization of D-T neutron generators in precise neutron experiments
Popis výsledku v původním jazyce
Using D-T generators as a neutron source for precise measurements requests a well-known neutron spectrum and spatial distribution of neutron flux. It is important in cross section measurements as well as in deep penetration issues. Thus, it is very important not only to validate the fluence accurately but also accurately validate the neutron spectrum in various positions. Experimental validation of two different D-T neutron generator experiments was performed using proton recoil method. Measurements performed at different angles and neutron generator voltages show relatively good agreement with the calculations. Despite the poor resolution, it was shown that stilbene is usable for the measurement of neutron energy shift due to changes in deuteron voltage.
Název v anglickém jazyce
The characterization of D-T neutron generators in precise neutron experiments
Popis výsledku anglicky
Using D-T generators as a neutron source for precise measurements requests a well-known neutron spectrum and spatial distribution of neutron flux. It is important in cross section measurements as well as in deep penetration issues. Thus, it is very important not only to validate the fluence accurately but also accurately validate the neutron spectrum in various positions. Experimental validation of two different D-T neutron generator experiments was performed using proton recoil method. Measurements performed at different angles and neutron generator voltages show relatively good agreement with the calculations. Despite the poor resolution, it was shown that stilbene is usable for the measurement of neutron energy shift due to changes in deuteron voltage.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN
0168-9002
e-ISSN
—
Svazek periodika
1034
Číslo periodika v rámci svazku
1 July 2022
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
15
Strana od-do
"166837(1)"-"166837(15)"
Kód UT WoS článku
000829843400013
EID výsledku v databázi Scopus
—