Statistical Evaluation of Transformation Methods Accuracy on Derived Pathological Vectorcardiographic Leads
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F22%3A10251914" target="_blank" >RIV/61989100:27240/22:10251914 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9756515" target="_blank" >https://ieeexplore.ieee.org/document/9756515</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/JTEHM.2022.3167009" target="_blank" >10.1109/JTEHM.2022.3167009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Statistical Evaluation of Transformation Methods Accuracy on Derived Pathological Vectorcardiographic Leads
Popis výsledku v původním jazyce
Objective: Vectorcardiography (VCG) as an alternative form of ECG provides important spatial information about the electrical activity of the heart. It achieves higher sensitivity in the detection of some pathologies such as myocardial infarction, ischemia and hypertrophy. However, vectorcardiography is not commonly measured in clinical practice, and for this reason mathematical transformations have been developed to obtain derived VCG leads, which in application in current systems and subsequent analysis can contribute to early diagnosis and obtaining other useful information about the electrical activity of the heart. Methods and procedures: The most frequently used transformation methods are compared, namely the Kors regression method, the Inverse Dower transformation, QLSV and the Quasi-orthogonal transformation. These transformation methods were used on 30 randomly selected records with a diagnosis of myocardial infarction from the Physikalisch-Technische Bundesanstalt (PTB) database and their accuracy was evaluated based on the calculation of the mean square error (MSE). MSE was subjected to statistical evaluation at a significance level of 0.05. Results: Based on statistical testing using the nonparametric multiselective Kruskall-Wallis test and subsequent post-hoc analysis using the Dunn method, the Kors regression as a whole method achieved the most accurate transformation. Conclusion: The results of statistical analysis provide an evaluation of the accuracy of several transformation methods for deriving orthogonal leads, for possible application in measuring and evaluation systems, which may contribute to the correct choice of method for subsequent analysis of electrical activity of the heart at orthogonal leads to predict various diseases.
Název v anglickém jazyce
Statistical Evaluation of Transformation Methods Accuracy on Derived Pathological Vectorcardiographic Leads
Popis výsledku anglicky
Objective: Vectorcardiography (VCG) as an alternative form of ECG provides important spatial information about the electrical activity of the heart. It achieves higher sensitivity in the detection of some pathologies such as myocardial infarction, ischemia and hypertrophy. However, vectorcardiography is not commonly measured in clinical practice, and for this reason mathematical transformations have been developed to obtain derived VCG leads, which in application in current systems and subsequent analysis can contribute to early diagnosis and obtaining other useful information about the electrical activity of the heart. Methods and procedures: The most frequently used transformation methods are compared, namely the Kors regression method, the Inverse Dower transformation, QLSV and the Quasi-orthogonal transformation. These transformation methods were used on 30 randomly selected records with a diagnosis of myocardial infarction from the Physikalisch-Technische Bundesanstalt (PTB) database and their accuracy was evaluated based on the calculation of the mean square error (MSE). MSE was subjected to statistical evaluation at a significance level of 0.05. Results: Based on statistical testing using the nonparametric multiselective Kruskall-Wallis test and subsequent post-hoc analysis using the Dunn method, the Kors regression as a whole method achieved the most accurate transformation. Conclusion: The results of statistical analysis provide an evaluation of the accuracy of several transformation methods for deriving orthogonal leads, for possible application in measuring and evaluation systems, which may contribute to the correct choice of method for subsequent analysis of electrical activity of the heart at orthogonal leads to predict various diseases.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Journal of Translational Engineering in Health and Medicine-JTEHM
ISSN
2168-2372
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
4/2022
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
nestrankovano
Kód UT WoS článku
000785734400001
EID výsledku v databázi Scopus
—