Popis výsledku v původním jazyce
The importance of power semiconductor converters steadily increases and as the use of converters grows, the risk of overvoltage damage also increases. The overvoltage protections are very important parts of electrical equipment containing power converters, e.g. inverters, connected especially to the grid lines. The grid line can originate the transient voltage induced by atmospheric phenomena, etc., which can be transmitted to the power converter. The overvoltage protection based on a mechanical spark system is very robust and simple, but not very precise for set up the break-down voltage. The electronically controlled overvoltage, e.g. crowbar, can operate precisely, but the auxiliary power sources for its control circuit are usually required. This article describes the active crowbar with a passive power supply of its controlled circuits. These control circuits operate directly on the power converter low voltage side and do not require any auxiliary power supply.
Název v anglickém jazyce
Crowbar Overvoltage Protection with Passive Power Supply of Control Circuit
Popis výsledku anglicky
The importance of power semiconductor converters steadily increases and as the use of converters grows, the risk of overvoltage damage also increases. The overvoltage protections are very important parts of electrical equipment containing power converters, e.g. inverters, connected especially to the grid lines. The grid line can originate the transient voltage induced by atmospheric phenomena, etc., which can be transmitted to the power converter. The overvoltage protection based on a mechanical spark system is very robust and simple, but not very precise for set up the break-down voltage. The electronically controlled overvoltage, e.g. crowbar, can operate precisely, but the auxiliary power sources for its control circuit are usually required. This article describes the active crowbar with a passive power supply of its controlled circuits. These control circuits operate directly on the power converter low voltage side and do not require any auxiliary power supply.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 IEEE 21st International Power Electronics and Motion Control Conference, PEMC 2024
ISBN
979-8-3503-8524-3
ISSN
2469-8741
e-ISSN
2473-0165
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Plzeň
Datum konání akce
30. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001346863100086