Possibility of the mine water utilization for the drinking purposes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27350%2F14%3A86089734" target="_blank" >RIV/61989100:27350/14:86089734 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Possibility of the mine water utilization for the drinking purposes
Popis výsledku v původním jazyce
Depending on the character and chemical composition of the mine water during specific conditions it can be used as an alternative source of drinking water. The mine water that was used for the experiment was taken at the mine water treatment plant Svatava at the brown coal deposit Sokolov (CZ) and had a character of partially treated water (increased pH value, precipitation of Fe, Al, Mn oxides/hydroxides). Tested mine water with pH value 7.2 and electrical conductivity value 120 mS.m-1 contains 105.8 mg.l-1 of Ca, 52.2 mg.l-1 of Mg, 0.5 mg.l-1of Fe and of 485.7 mg.l-1 of SO42-. The mine water samples have been treated according to the requirements for drinking water quality by ion exchange resin technique. During column experiments strongly acidic catex Amberlite IR 120 H+ and weakly basic annex Purolite A-100 OH- has been used. All together 30 litres of mine water has been treated and the exchange capacity of the used resin content (400 ml) has not been exhausted. The treated mine wa
Název v anglickém jazyce
Possibility of the mine water utilization for the drinking purposes
Popis výsledku anglicky
Depending on the character and chemical composition of the mine water during specific conditions it can be used as an alternative source of drinking water. The mine water that was used for the experiment was taken at the mine water treatment plant Svatava at the brown coal deposit Sokolov (CZ) and had a character of partially treated water (increased pH value, precipitation of Fe, Al, Mn oxides/hydroxides). Tested mine water with pH value 7.2 and electrical conductivity value 120 mS.m-1 contains 105.8 mg.l-1 of Ca, 52.2 mg.l-1 of Mg, 0.5 mg.l-1of Fe and of 485.7 mg.l-1 of SO42-. The mine water samples have been treated according to the requirements for drinking water quality by ion exchange resin technique. During column experiments strongly acidic catex Amberlite IR 120 H+ and weakly basic annex Purolite A-100 OH- has been used. All together 30 litres of mine water has been treated and the exchange capacity of the used resin content (400 ml) has not been exhausted. The treated mine wa
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
SGEM 2014 : 14th International Multidisciplinary Scientific Geoconference : Geoconference on Water Resources. Forest, Marine and Ocean Ecosystems : 17-26, June, 2014, Albena, Bulgaria : conference proceedings. Volume I, Hydrology and water resources
ISBN
978-619-7105-13-1
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
6
Strana od-do
533-538
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
17. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—