Field Application for EPR Tecnique to Study Interganular Corrosion Sensbility.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F00%3A00011852" target="_blank" >RIV/61989100:27360/00:00011852 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Field Application for EPR Tecnique to Study Interganular Corrosion Sensbility.
Popis výsledku v původním jazyce
Double loop electrochemical potentiokinetic reactivation (DL-EPR) method for measuring of the sensitization of materials can be used "in situ". DL-EPR has been applied as a quantitative method for non?destructive measuring of the degree of sensitizationin weld affected zones of stainless steels and/or related alloys (304L, 904L, 444, Alloy 800) with a miniaturized electrochemical field cell using a gel electrolyte containing sulphuric acid and potassium thiocyanate. The results are compared with standard electrochemical tests with a liquid electrolyte employed for the mentioned materials. A good correlation between reactivation ratios (Jr/Jp) and the distances from the weld axes were obtained for gel and liquid electrolyte. The DL-EPR method results were also compared with the immersion tests of tested materials in standard boiling solutions. The metallography inspection was focused on intergranular depth penetration in relation with the reactivation ratios.
Název v anglickém jazyce
Field Application for EPR Tecnique to Study Interganular Corrosion Sensbility.
Popis výsledku anglicky
Double loop electrochemical potentiokinetic reactivation (DL-EPR) method for measuring of the sensitization of materials can be used "in situ". DL-EPR has been applied as a quantitative method for non?destructive measuring of the degree of sensitizationin weld affected zones of stainless steels and/or related alloys (304L, 904L, 444, Alloy 800) with a miniaturized electrochemical field cell using a gel electrolyte containing sulphuric acid and potassium thiocyanate. The results are compared with standard electrochemical tests with a liquid electrolyte employed for the mentioned materials. A good correlation between reactivation ratios (Jr/Jp) and the distances from the weld axes were obtained for gel and liquid electrolyte. The DL-EPR method results were also compared with the immersion tests of tested materials in standard boiling solutions. The metallography inspection was focused on intergranular depth penetration in relation with the reactivation ratios.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JK - Koroze a povrchové úpravy materiálu
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F98%2F0182" target="_blank" >GA106/98/0182: Výzkum elektrochemické polarizační potenciokinetické reaktivační metody (EPR) pro kontrolu vysokolegovaných korozivzdorných materiálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Int. Symposium on MAterials and Life MAnagement, ISOMALM 2000
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Eds. Baldev Raj, K. Bhanu Sankara Rao
Místo vydání
Chenai, India
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—