Vliv vodíku na mikrostrukturní vlastnosti Ti slitin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F07%3A00016300" target="_blank" >RIV/61989100:27360/07:00016300 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of hydrogen on the microstructure features of Ti based alloys
Popis výsledku v původním jazyce
Study of hydrogen effect on microstructure and mechanical features of TiAl- and NiTi-based alloys was performed. Specimens of polycrystalline alloys were observed in following states: as-received and after heat treatments in different atmospheres. The annealing in flowing argon or hydrogen gas was realised at 750°C for 4 hours in case of Ti-46Al-1.5Mo-0.2C and Ti-44Al-8Nb alloys and at 850°C for 1 hour in case of NiTi, NiTi-Cu and NiTi-Fe alloys. Microstructure was studied using light and scanning electron microscopies. Measurements of microhardness completed the metallographic study of Ti-Al based alloys. The NiTi wires were tensile tested in air at room temperature and strain rate of 3 x 10-4 s-1 and fracture surfaces were observed using SEM. AFM topography of martensite plates in NiTi as well as of lamellar structure in TiAl studied in order to determine the hydrogen influence. The quantity of hydrogen was determined by gas desorption at 700°C in vacuum desorption apparatus.
Název v anglickém jazyce
Effect of hydrogen on the microstructure features of Ti based alloys
Popis výsledku anglicky
Study of hydrogen effect on microstructure and mechanical features of TiAl- and NiTi-based alloys was performed. Specimens of polycrystalline alloys were observed in following states: as-received and after heat treatments in different atmospheres. The annealing in flowing argon or hydrogen gas was realised at 750°C for 4 hours in case of Ti-46Al-1.5Mo-0.2C and Ti-44Al-8Nb alloys and at 850°C for 1 hour in case of NiTi, NiTi-Cu and NiTi-Fe alloys. Microstructure was studied using light and scanning electron microscopies. Measurements of microhardness completed the metallographic study of Ti-Al based alloys. The NiTi wires were tensile tested in air at room temperature and strain rate of 3 x 10-4 s-1 and fracture surfaces were observed using SEM. AFM topography of martensite plates in NiTi as well as of lamellar structure in TiAl studied in order to determine the hydrogen influence. The quantity of hydrogen was determined by gas desorption at 700°C in vacuum desorption apparatus.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
METAL 2007, 16. mezinárodní konference metalurgie a materiálů
ISBN
978-80-86840-33-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
95-95
Název nakladatele
Tanger spol. s r.o.
Místo vydání
Ostrava
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—